View : 185 Download: 0

Voltage-sensitive activities of ion-channel-coupled receptors integrated with budded baculovirus in bioelectronic nose devices

Title
Voltage-sensitive activities of ion-channel-coupled receptors integrated with budded baculovirus in bioelectronic nose devices
Authors
Park, Inkyoung; Kim, So-ong; Park, Yongjun; Choi, Yoonji; Bang, Sunwoo; Lee, Seung Hwan; Moreau, Christophe; Park, Tai Hyun; Hong, Seunghun
Ewha Authors
박태현
SCOPUS Author ID
박태현scopus
Issue Date
2026
Journal Title
NANO TODAY
ISSN
1748-0132JCR Link

1878-044XJCR Link
Citation
NANO TODAY vol. 69
Keywords
Bioelectronic nose; Ion-channel-coupled receptor; Baculovirus; G protein-coupled receptor; Carbon nanotube field-effect transistor
Publisher
ELSEVIER SCI LTD
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Voltage-sensitive ion-channel-coupled receptors (ICCRs) are integrated with budded baculovirus particles (BBVs) for the amplification of bioelectronic nose signals via external voltage stimulation. Here, BBVs are employed as stable and uniform nanoscaffolds to introduce ICCRs into field-effect transistor devices, providing a direct alternative to conventional nanovesicle-based membrane platforms. ICCRs composed of human olfactory receptors (hOR2AG1) and potassium ion channels (Kir6.2) are transfected into BBV membranes, and then, the BBVs are immobilized on the channel region of a carbon nanotube field-effect transistor (CNT-FET). In this hybrid device, voltage-dependent ion channel gating behavior can be triggered by the stimulation of liquid gate voltages (VLG) to BBV membranes. The opening of ion channels leads to local fluctuations in junction potential between the BBV membrane and the CNT channel, which can be observed by changes in the channel conductance. Importantly, receptor-ligand binding activities of ICCR in BBV membranes can be modulated by applying different VLG values. The EC50 values for the receptor-ligand binding are estimated as 204 pM, 70.8 fM, and 1.4 fM for VLG of -80 mV, -120 mV, and -180 mV, respectively. This voltage-dependent modulation originates from changes in the BBV membrane potential, which alter the receptor binding affinity and reduce the ligand concentration required to induce a half-maximal sensor response into femtomolar ranges. Thus, our strategy can be utilized to achieve tunable signal amplification capabilities of bioelectronic nose device.
DOI
10.1016/j.nantod.2026.103046
Appears in Collections:
신산업융합대학 > 식품영양학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE