Enhanced TOC removal from paper mill wastewater using air dielectric barrier discharge plasma with persulfate sources: Mechanistic insights and continuous flow operation performance evaluation

Title
Enhanced TOC removal from paper mill wastewater using air dielectric barrier discharge plasma with persulfate sources: Mechanistic insights and continuous flow operation performance evaluation
Authors
Abd Rahman N.; Valiyaveettil Basheer R.; Yoon S.Y.; Choong C.E.; Hong Y.J.; Yoon Y.; Choi E.H.; Jang M.
Ewha Authors
윤여민
SCOPUS Author ID
윤여민scopus
Issue Date
2025
Journal Title
Journal of Hazardous Materials
ISSN
0304-3894JCR Link
Citation
Journal of Hazardous Materials vol. 486
Keywords
Air DBD plasma; Cost analysis; Demineralization; Persulfate activation; ROS identification
Publisher
Elsevier B.V.
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
This study investigates the removal of total organic carbon (TOC) from paper mill wastewater using air dielectric barrier discharge (DBD) plasma, combined with various persulfate sources, namely potassium peroxymonosulfate (PMS), potassium peroxydisulfate (PDS), and sodium persulfate (SPS). Mechanistic insights into the activation of plasma-PDS and -PMS were obtained through quenching experiments and electron spin resonance (ESR) techniques. The addition of persulfate to air DBD plasma increased TOC removal kinetics by approximately 1.7–3 times, with plasma-PDS exhibiting the highest synergistic factor of 3.14. The electric field from the plasma significantly enhanced radical production, with plasma-PDS outperforming plasma-PMS due to its higher generation of sulfate (SO4•−) and hydroxyl radicals (•OH), which are more effective at breaking down complex organic compounds in paper mill wastewater. In continuous-flow experiments, the plasma-PDS process with 10 mM and a 90-minute retention time achieved a 94.5 % TOC removal efficiency for actual paper mill wastewater over 8 h operation, demonstrating its effectiveness and stability for extended treatment. Quenching experiments revealed that electrons play a key role in PDS activation, whereas 1O2 is crucial for PMS activation. © 2024 Elsevier B.V.