View : 556 Download: 0

Imaging oersted field around current flowing wire based on a diamond scanning magnetometer

Title
Imaging oersted field around current flowing wire based on a diamond scanning magnetometer
Authors
Lee Y.Lee M.Jo J.Lee S.Yoo J.-W.Choi T.Heinrich A.Lee D.
Ewha Authors
Andreas Heinrich최태영
SCOPUS Author ID
Andreas Heinrichscopus; 최태영scopus
Issue Date
2022
Journal Title
Current Applied Physics
ISSN
1567-1739JCR Link
Citation
Current Applied Physics vol. 34, pp. 59 - 63
Keywords
Diamond NV centerImaging current flowScanning magnetometer
Publisher
Elsevier B.V.
Indexed
SCIE; SCOPUS; KCI WOS scopus
Document Type
Article
Abstract
We demonstrate imaging current flow in a transport device by measuring the current-induced Oersted field. A diamond scanning magnetometer that hosts a single nitrogen-vacancy (NV) center at the tip apex is used to obtain the image. We fabricate a U-shape of Pt wire and study evolution of the Oersted field as the current continuously changes its direction along the wire. We find a good agreement between the obtained results and the simulated images based on the Biot-Savart law. In order to show the capability of imaging different field components, we perform the same experiment but with two different axes of the NV center. This work provides a novel imaging method of the current profile and can be applied to various transport experiments. © 2021 Korean Physical Society
DOI
10.1016/j.cap.2021.12.001
Appears in Collections:
자연과학대학 > 물리학전공 > Journal papers
Files in This Item:
There are no files associated with this item.