View : 442 Download: 0

Optimization and validation of capillary electrophoresis- and gas chromatography-tandem mass spectrometry methods for the analysis of intermediate metabolites in glycolysis and pentose phosphate pathways within biological samples

Title
Optimization and validation of capillary electrophoresis- and gas chromatography-tandem mass spectrometry methods for the analysis of intermediate metabolites in glycolysis and pentose phosphate pathways within biological samples
Authors
Nam, MisoKim, Min-SunHwang, Geum-Sook
Ewha Authors
황금숙
SCOPUS Author ID
황금숙scopus
Issue Date
2021
Journal Title
JOURNAL OF CHROMATOGRAPHY A
ISSN
0021-9673JCR Link

1873-3778JCR Link
Citation
JOURNAL OF CHROMATOGRAPHY A vol. 1656
Keywords
Intermediates of glycolysis and pentose phosphate pathwaysCE-MS/MSGC-MS/MSMethod validationHuman serumCell extract
Publisher
ELSEVIER
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Highly selective methods for the analysis of intermediate metabolites involved in glycolysis and phosphate pentose pathways are essential for metabolism and metabolic flux studies. However, the successful separation of phosphorylated compounds is difficult due to their high polarity, as well as their structural isomers. In this study, phosphorylated compounds in spiked serum samples were analyzed using capillary electrophoresis tandem mass spectrometry (CE-MS/MS) and gas chromatography (GC)-MS/MS. Following liquid-liquid extraction, ultrafiltration and derivatization steps were needed to perform CE-MS/MS and GC-MS/MS, respectively. The CE-MS/MS method allowed for the identification and quantification of all 15 biologically important phosphorylated compounds, whereas only 13 compounds were identified and quantified by GC-MS/MS. Both methods demonstrated wide linear ranges, good interday (< 9.6%: CE-MS/MS; < 14.7%: GC-MS/MS) and intraday (< 13.0%: CE-MS/MS; < 14.9%: GC-MS/MS) variability, and limits of detection (LODs) in the ranges of 0.25-2 and 0.05-0.5 mu mol/L for CE-MS/MS and GC-MS/MS, respectively. In the phosphorylated compound stability test, the instability of glyceraldehyde 3-phosphate (GA3P) and dihydroxyacetone phosphate (DHAP) was observed during freeze-thaw and long-term storage due to reversible isomerization. The results of CE-MS/MS and GC-MS/MS analysis showed that the concentrations of phosphorylated compounds determined using the two methods matched closely, while that of glycerol 3-phosphate (G3P) showed some variability in cell extracts. Therefore, while both CE- MS/MS and GC-MS/MS are suitable for analyzing metabolites resulting from the glycolysis and pentose phosphate pathways, additional validation is needed for some compounds, depending on the background matrix. (C) 2021 Published by Elsevier B.V.
DOI
10.1016/j.chroma.2021.462531
Appears in Collections:
자연과학대학 > 화학·나노과학전공 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE