dc.description.abstract | The purpose of this study was to compare insulation performance between a base case that applied the existing steel pipe frame and an alternative case that reduced thermal bridging by applying a truss-shaped insulation frame (TIF) to a back frame type curtain wall. Insulation performance was compared by obtaining the effective U-factor and the lowest indoor surface temperature through a three-dimensional steady-state heat transfer simulation. In addition, mock-up tests were performed to compare the U-factors of the base case and alternative case. The simulation results showed that the effective U-factor of the alternative case was 36% lower than in the base case, a significant heat loss reduction. The lowest indoor surface temperature of the alternative case was 0.5 degrees C higher than in the base case, showing that the surface condensation risk also decreased. In the mock-up test results, the alternative case U-factor was 33% lower than in the base case, confirming the associated large heat loss reduction. For the base case, both the effective U-factor by simulation and the U-factor by the mock-up test were much higher than the design U-factor according to the Korean Design Standard, which neglects thermal bridging, indicating a significantly increased heat loss caused by this factor. For the alternative case, however, both U-factors were similar to the design U-factor. | * |
dc.language | English | * |
dc.publisher | MDPI | * |
dc.subject | thermal insulation | * |
dc.subject | thermal bridge | * |
dc.subject | curtain wall | * |
dc.subject | truss-shaped insulation frame | * |
dc.title | Insulation Performance Comparison of Curtain Wall Systems with Existing Pipe Frames and Truss-Shaped Insulation Frames | * |
dc.type | Article | * |
dc.relation.issue | 15 | * |
dc.relation.volume | 14 | * |
dc.relation.index | SCIE | * |
dc.relation.index | SCOPUS | * |
dc.relation.journaltitle | ENERGIES | * |
dc.identifier.doi | 10.3390/en14154682 | * |
dc.identifier.wosid | WOS:000681838300001 | * |
dc.author.google | Choi, Bo-Hye | * |
dc.author.google | Song, Seung-Yeong | * |
dc.contributor.scopusid | 송승영(14626984500) | * |
dc.date.modifydate | 20240319094649 | * |