View : 663 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author배승진*
dc.contributor.author임경민*
dc.contributor.author이동환*
dc.date.accessioned2019-08-27T16:30:09Z-
dc.date.available2019-08-27T16:30:09Z-
dc.date.issued2019*
dc.identifier.issn0273-2300*
dc.identifier.issn1096-0295*
dc.identifier.otherOAK-25278*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/251310-
dc.description.abstractWe aimed to conduct additional statistical analysis of the reproducibility and predictive capacity of MCTT HCE (TM) eye irritation test (EIT), a me-too test method for OECD TG 492 with the data generated during the validation study in which 30 reference chemicals were tested in three repeated runs by three independent laboratories. We evaluated the within-laboratory reproducibility (WLR) and the between-laboratory reproducibility (BLR) through tabulation and graphs and presented the concordance of eye irritancy prediction with 95% Wilson's confidence intervals (CIs). Also, the analyses of the Intra-Class Correlation Coefficient (ICC) and Bland-Altman plot were applied to confirm the reproducibility and the comparability, referring to the validated methods of OECD TG 492. Kappa analysis was also performed to check the degree of agreement of the within- and between-laboratory reproducibility and agreement between MCTT HCE (TM) EIT and the reference methods. We calculated the predictive capacity via misprediction over total prediction method. The predictive capacity (sensitivity, specificity, and accuracy) was presented with 95% of Wilson's CIs. Also, bootstrap resampling was performed to express the 95% CI by the simple percentile methods for 30 chemicals and 141 reference chemicals additionally tested. Collectively, WLR (92.2%) and BLR (93.3%) met the criteria of the performance standards (WLR >= 90% and BLR >= 85%), and the results of ICC analysis and the Bland-Altman plot suggested an acceptable WLR and BLR and comparability to other validated methods of OECD TG 492. Also, the predictive capacity results for the 30 reference chemicals confirmed the good performance of the MCTT HCE (TM) EIT by satisfying the criteria of sensitivity, specificity, and the accuracy stated in the PS. The bootstrap resampling method showed a predictive capacity, sufficiently satisfying the criteria stated in the Performance Standards.*
dc.languageEnglish*
dc.publisherACADEMIC PRESS INC ELSEVIER SCIENCE*
dc.subjectMCTT HCE (TM) eye irritation test*
dc.subjectOECD TG 492*
dc.subjectReproducibility*
dc.subjectPredictive capacity*
dc.subjectBland-Altman*
dc.subjectIntra-class correlation coefficient*
dc.subjectBootstrapping resampling*
dc.titleStatistical analysis of the reproducibility and predictive capacity of MCTT HCE (TM) eye irritation test, a me-too test method for OECD TG 492*
dc.typeArticle*
dc.relation.volume107*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.journaltitleREGULATORY TOXICOLOGY AND PHARMACOLOGY*
dc.identifier.doi10.1016/j.yrtph.2019.104430*
dc.identifier.wosidWOS:000513225500034*
dc.identifier.scopusid2-s2.0-85069629270*
dc.author.googleLim, Song-E*
dc.author.googleLee, Donghwan*
dc.author.googleBae, SeungJin*
dc.author.googleLim, Kyung-Min*
dc.contributor.scopusid배승진(12143102400)*
dc.contributor.scopusid임경민(8916551700)*
dc.contributor.scopusid이동환(56434427300;58539708000)*
dc.date.modifydate20240220115649*
Appears in Collections:
약학대학 > 약학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE