View : 874 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author김정호*
dc.contributor.author박성민*
dc.contributor.author이은희*
dc.date.accessioned2017-06-13T01:06:21Z-
dc.date.available2017-06-13T01:06:21Z-
dc.date.issued2017*
dc.identifier.issn1530-437X*
dc.identifier.issn1558-1748*
dc.identifier.otherOAK-20633*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/235292-
dc.description.abstractA portable system for fluorescence measurement has been developed for cyanobacteria detection. Exploiting commercially available low-cost photodiodes and a single 9 V supply, the system was able to measure two fluorescence emissions simultaneously. Output voltages resulting from the fluorescence intensity were measured by utilizing two quantum dots of QD(565) and QD(655). These quantum dots were employed into a NanoGene assay for mcyD gene (synthetase of toxic microcystin) detection of Microcystis aeruginosa. We investigated various operational parameters (e. g., distance, angle between laser emission and sample, and so on) for the proposed system. Measurements indicated the highest output voltage signal was obtained at a distance of 0.5 cm with the right angle (90 degrees) between the laser source and a sample vial. Also, the mcyD gene hybridized with QD(565) and QD(655) was quantitatively detected by the proposed detection system, i. e., the normalized output voltage (QD(655)/QD(565)) was linearly proportional to the mcyD gene copy numbers (y = 0.41 log x + 6.6, r(2) = 0.92). Finally, the quantitative data were transferred wirelessly to the readout via Bluetooth.*
dc.languageEnglish*
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC*
dc.subjectCyanobacteria*
dc.subjectdetection*
dc.subjectfluorescence*
dc.subjectMicrocystis aeruginosa*
dc.subjectquantum dots*
dc.subjecttransducer kit*
dc.titlePortable Fluorometer for Cyanobacteria Detection*
dc.typeArticle*
dc.relation.issue8*
dc.relation.volume17*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage2377*
dc.relation.lastpage2384*
dc.relation.journaltitleIEEE SENSORS JOURNAL*
dc.identifier.doi10.1109/JSEN.2017.2672993*
dc.identifier.wosidWOS:000398890800011*
dc.author.googleKim, Seung-Hoon*
dc.author.googleHe, Ying*
dc.author.googleLee, Eun-Hee*
dc.author.googleKim, Jeong-Ho*
dc.author.googlePark, Sung Min*
dc.contributor.scopusid김정호(57202767594)*
dc.contributor.scopusid박성민(7501832231)*
dc.contributor.scopusid이은희(55773710100;56141882500)*
dc.date.modifydate20240322125332*
Appears in Collections:
공과대학 > 전자전기공학전공 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE