View : 805 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author배승진*
dc.contributor.author임경민*
dc.date.accessioned2016-11-15T02:11:26Z-
dc.date.available2016-11-15T02:11:26Z-
dc.date.issued2016*
dc.identifier.issn0273-2300*
dc.identifier.issn1096-0295*
dc.identifier.otherOAK-19621*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/232619-
dc.description.abstractLocal lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple end-points with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. (C) 2016 Elsevier Inc. All rights reserved.*
dc.languageEnglish*
dc.publisherACADEMIC PRESS INC ELSEVIER SCIENCE*
dc.subjectPerformance standards*
dc.subjectValidation study*
dc.subjectLocal lymph node assay*
dc.subjectLLNA: BrdU-FCM*
dc.subjectSkin sensitization*
dc.subjectFlow cytometry*
dc.titlePerformance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method*
dc.typeArticle*
dc.relation.volume80*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage183*
dc.relation.lastpage194*
dc.relation.journaltitleREGULATORY TOXICOLOGY AND PHARMACOLOGY*
dc.identifier.doi10.1016/j.yrtph.2016.06.009*
dc.identifier.wosidWOS:000383314900017*
dc.author.googleAhn, Ilyoung*
dc.author.googleKim, Tae-Sung*
dc.author.googleJung, Eun-Sun*
dc.author.googleYi, Jung-Sun*
dc.author.googleJang, Won-Hee*
dc.author.googleJung, Kyoung-Mi*
dc.author.googlePark, Miyoung*
dc.author.googleJung, Mi-Sook*
dc.author.googleJeon, Eun-Young*
dc.author.googleYeo, Kyeong-uk*
dc.author.googleJo, Ji-Hoon*
dc.author.googlePark, Jung-Eun*
dc.author.googleKim, Chang-Yul*
dc.author.googlePark, Yeong-Chul*
dc.author.googleSeong, Won-Keun*
dc.author.googleLee, Ai Young*
dc.author.googleChun, Young Jin*
dc.author.googleJeong, Tae Cheon*
dc.author.googleJeung, Eui Bae*
dc.author.googleLim, Kyung-Min*
dc.author.googleBae, SeungJin*
dc.author.googleSohn, Soojung*
dc.author.googleHeo, Yong*
dc.contributor.scopusid배승진(12143102400)*
dc.contributor.scopusid임경민(8916551700)*
dc.date.modifydate20240426142423*
Appears in Collections:
약학대학 > 약학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE