View : 492 Download: 0

Development of a biodegradable sirolimus-eluting stent coated by ultrasonic atomizing spray

Title
Development of a biodegradable sirolimus-eluting stent coated by ultrasonic atomizing spray
Authors
Kim S.-J.Park J.-G.Kim J.H.Heo J.S.Choi J.-W.Jang Y.-S.Yoon J.Lee S.J.Kwon I.K.
Ewha Authors
이승진
SCOPUS Author ID
이승진scopus
Issue Date
2011
Journal Title
Journal of Nanoscience and Nanotechnology
ISSN
1533-4880JCR Link
Citation
Journal of Nanoscience and Nanotechnology vol. 11, no. 7, pp. 5689 - 5697
Indexed
SCI; SCIE; SCOPUS WOS scopus
Document Type
Conference Paper
Abstract
In this study, poly(D,L lactic-co-glycolic acid) (PLGA) was used as a drug carrier to generate two types of stents loaded with different concentrations of sirolimus. These stents were prepared by ultrasonic atomizing spray coating. Ultrasonic atomizing spray nozzle uses a low-pressure air/gas to produce a soft, highly focused beam of small spray drops. An isolated hypotube delivers liquid to the nozzle's atomizing surface while air/gas, delivered through the nozzle orifice at a fixed low pressure, shapes the atomized drops into a very precise, targeted spray. The stent was moved both in the traverse direction and rotated during the spraying process. The morphology of the sirolimus-eluting stents was examined by scanning electron microscopy (SEM) which indicated that the coating was very smooth and uniform. The coating was found to have the ability to withstand the compressive and tensile strains imparted without cracking during the stent inflation process. Release profile of sirolimus was measured by high performance liquid chromatography (HPLC). The release behavior of sirolimus from the stent surface had a two phase release profile with a burst release period of about 2 days, followed by a sustained and slow release phase. The mass loss behavior of PLGA appeared linear throughout most of the degradation period. At 28 days, neointimal formation was found to be significantly decreased for both sirolimus-eluting stents as compared to bare-metal stents (BMS). Assessment of vascular healing revealed an absence of increased inflammation in both sirolimus-eluting stents. Inflammation is commonly observed in drug-eluting stents (DES) with nonbiodegradable polymeric coatings. Taking these results into account, these novel sirolimus-eluting stents may be good candidates to resolve in-stent restenosis. Copyright © 2011 American Scientific Publishers All rights reserved.
DOI
10.1166/jnn.2011.4496
Appears in Collections:
약학대학 > 약학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE