View : 221 Download: 0

In Vitro Diagnostics Certification for Creatinine Assays in Korea over 7 Years: Achievements and Future Outlook

Title
In Vitro Diagnostics Certification for Creatinine Assays in Korea over 7 Years: Achievements and Future Outlook
Authors
Cho, Eun-Jung; Yu, Joonsang; Ryu, Jeayeon; Seo, Jiwoo; Lee, Hyunae; Cho, Chan-Ik; Jeong, Tae-Dong; Kim, Sollip; Lee, Woochang; Chun, Sail; Min, Won-Ki
Ewha Authors
정태동
SCOPUS Author ID
정태동scopus
Issue Date
2025
Journal Title
ANNALS OF LABORATORY MEDICINE
ISSN
2234-3806JCR Link

2234-3814JCR Link
Citation
ANNALS OF LABORATORY MEDICINE vol. 45, no. 5, pp. 493 - 502
Keywords
Accuracy; Bias; Certification; Creatinine; IVD manufacturer; Laboratory network
Publisher
KOREAN SOC LABORATORY MEDICINE
Indexed
SCIE; SCOPUS; KCI WOS
Document Type
Article
Abstract
Background: An international reference measurement laboratory network for creatinine (Cr) is lacking; therefore, Korea developed an independent evaluation and certification system. The in vitro diagnostics (IVD) certification program, launched in 2017, formed part of a broader Cr standardization initiative intended to enhance accuracy at the manufacturing stage. Methods: The program was designed to evaluate analytical systems, including all reagent lots, calibrators, and instrument models, twice annually. Bias, imprecision, total error (TE), and linearity were evaluated based on established acceptance criteria. A post-certification process allows submission for a second challenge and validation of corrective actions. Results: Between 2017 and 2023, 489 analytical systems were evaluated. Average acceptance rates for bias, imprecision, TE, and linearity were 70.8%, 95.9%, 87.7%, and 87.8%, respectively. The lowest acceptance rate for bias evaluation was 8.7% for the kinetic Jaffe method without compensation in 2018. Over the 7-year period, the mean absolute percentage bias (absBias%), coefficient of variation (CV), and TE were 4.62%, 1.37%, and 7.29%, respectively. The highest absBias% (7.94%) was observed in the 0.0 <= Cr< 1.0 target value range. Since 2019, a consistent reduction in absBias% has been observed. Conclusions: This program is a pioneering response to the absence of a global certification program for Cr assays. It offers significant advantages, including comprehensive evaluations, fee-free participation, and a robust post-certification process. Continuous participation and improvement efforts by manufacturers have contributed to enhanced accuracy in Cr assays.
DOI
10.3343/alm.2024.0654
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE