View : 236 Download: 0

Early termination of six-min walk test in COPD as simple prognostic marker vs. BODE index

Title
Early termination of six-min walk test in COPD as simple prognostic marker vs. BODE index
Authors
Youk, Chan Soo; Kim, Deog Kyeom; Rhee, Chin Kook; Choi, Cheon Woong; Lim, Seong Yong; Kim, Sang Hoon; Lee, Jin Hwa; Yoon, Hyoung Kyu; Ha Yoo, Kwang; An, Tai Joon|Korean COPD Subgroup Study Grp
Ewha Authors
이진화
SCOPUS Author ID
이진화scopus
Issue Date
2025
Journal Title
RESPIRATORY MEDICINE
ISSN
0954-6111JCR Link

1532-3064JCR Link
Citation
RESPIRATORY MEDICINE vol. 250
Keywords
Pulmonary disease; Chronic obstructive; Exercise test; Exercise tolerance; Prognosis; Patient outcome assessment
Publisher
W B SAUNDERS CO LTD
Indexed
SCIE; SCOPUS WOS
Document Type
Article
Abstract
Background: The 6-min walk test (6MWT) is commonly used to assess functional capacity in chronic obstructive pulmonary disease (COPD). While total distance walked is the main metric, early termination-stopping before 6 min-may reflect systemic vulnerability. This study evaluated whether early termination predicts poor outcomes and compared its prognostic value with the BODE index. Methods: Data were derived from a Korean COPD multicenter prospective cohort involving 55 hospitals. A total of 2085 patients were included in the present analysis. Early termination was defined as stopping the 6MWT before 6 min due to symptoms or clinical decision. Primary outcomes were acute exacerbations (AEs) of COPD; secondary outcomes included 3-year mortality and longitudinal changes in forced expiratory volume in 1 s (FEV1), COPD Assessment Test (CAT), and St. George's Respiratory Questionnaire for COPD (SGRQ-C) scores. Analyses included regression models, receiver operating characteristic curve, and propensity score matching. Results: Early termination occurred in 132 patients (6.3 %). They had lower post-BD FEV1 (48.4 % vs. 59.2 %) and higher symptom burden (CAT and SGRQ-C, all P < 0.01). Early termination was associated with increased risk of moderate (adjusted incidence rate ratio [aIRR] 1.60-1.65) and severe AEs (aIRR 2.19-2.39), and higher 3-year mortality (9.5 % vs. 4.6 %, log-rank P = 0.04). Its prognostic performance was comparable to the BODE index (DeLong P > 0.05). Conclusion: Early termination during the 6MWT is a simple, practical marker of poor outcomes in COPD, offering prognostic value comparable to the BODE index and aiding risk stratification when full assessment is impractical.
DOI
10.1016/j.rmed.2025.108538
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE