Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김진실 | * |
| dc.date.accessioned | 2025-10-29T16:30:06Z | - |
| dc.date.available | 2025-10-29T16:30:06Z | - |
| dc.date.issued | 2025 | * |
| dc.identifier.issn | 2288-5943 | * |
| dc.identifier.other | OAK-38083 | * |
| dc.identifier.uri | https://dspace.ewha.ac.kr/handle/2015.oak/273187 | - |
| dc.description.abstract | This study highlights the role of intraoperative sonography (IOS) using a high-frequency transducer in living donor liver transplantation (LDLT) with modified right-lobe grafts. IOS is pivotal for the real-time assessment of vascular patency and anastomotic integrity, providing crucial insights into hepatic artery, portal vein, and hepatic vein configurations. The technique's high spatial resolution allows for the early detection of potential vascular complications, which are significant predictors of postoperative outcomes. Through detailed illustrations of vascular anastomoses and hemodynamics, this article discusses technical and anatomical considerations of IOS and demonstrates its effectiveness in screening and managing vascular complications in LDLT, thereby enhancing surgical precision and patient safety. © 2025 Elsevier B.V., All rights reserved. | * |
| dc.language | English | * |
| dc.publisher | Korean Society of Ultrasound in Medicine | * |
| dc.subject | Graft Survival | * |
| dc.subject | Liver Transplantation | * |
| dc.subject | Ultrasongraphy | * |
| dc.subject | Vascular Patency | * |
| dc.subject | Polytetrafluoroethylene | * |
| dc.subject | Adult | * |
| dc.subject | Anastomosis | * |
| dc.subject | Article | * |
| dc.subject | Blood Flow | * |
| dc.subject | Blood Vessel Shunt | * |
| dc.subject | Clinical Article | * |
| dc.subject | Computer Assisted Tomography | * |
| dc.subject | Doppler Flowmetry | * |
| dc.subject | Echography | * |
| dc.subject | Hepatectomy | * |
| dc.subject | Hepatic Artery | * |
| dc.subject | Human | * |
| dc.subject | Liver Vein | * |
| dc.subject | Living Donor | * |
| dc.subject | Patient Safety | * |
| dc.subject | Thrombosis | * |
| dc.subject | Ultrasound | * |
| dc.subject | Vascularization | * |
| dc.title | Intraoperative sonography using high-frequency transducer during living Donor liver transplantation with modified right-lobe graft | * |
| dc.type | Article | * |
| dc.relation.issue | 4 | * |
| dc.relation.volume | 44 | * |
| dc.relation.index | SCOPUS | * |
| dc.relation.index | KCI | * |
| dc.relation.startpage | 294 | * |
| dc.relation.lastpage | 303 | * |
| dc.relation.journaltitle | Ultrasonography | * |
| dc.identifier.doi | 10.14366/usg.25047 | * |
| dc.identifier.wosid | WOS:001511778000001 | * |
| dc.identifier.scopusid | 2-s2.0-105009947864 | * |
| dc.author.google | Kim J.S. | * |
| dc.author.google | Kim K. | * |
| dc.author.google | Choi E. | * |
| dc.author.google | Song G. | * |
| dc.contributor.scopusid | 김진실(57189764787) | * |
| dc.date.modifydate | 20260811140005 | * |