View : 324 Download: 0
Clinical Outcome of Cryoballoon Ablation for Long-Standing Persistent Atrial Fibrillation: From the Korean Cryballoon Ablation Registry
- Title
- Clinical Outcome of Cryoballoon Ablation for Long-Standing Persistent Atrial Fibrillation: From the Korean Cryballoon Ablation Registry
- Authors
- Lee, Sung Ho; Moon, Suhyeon; Cha, Myung-Jin; Lee, So-Ryoung; Kim, Ju Youn; Kwon, Chang Hee; Shim, Jaemin; Park, Junbeom; Kim, Ki-Hun; Yang, Pil-Sung; Kim, Jun-Hyung; Oh, Il-Young; Lim, Hong Euy
- Ewha Authors
- 박준범
- SCOPUS Author ID
- 박준범

- Issue Date
- 2025
- Journal Title
- JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY
- ISSN
- 1045-3873
1540-8167
- Citation
- JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY vol. 36, no. 1, pp. 246 - 255
- Keywords
- atrial fibrillation; cryoballoon ablation; long-standing; pulmonary vein isolation
- Publisher
- WILEY
- Indexed
- SCIE; SCOPUS

- Document Type
- Article
- Abstract
- Introduction Pulmonary vein isolation (PVI) by cryoballoon ablation (CBA) is considered an effective primary strategy for early persistent atrial fibrillation (AF). However, data regarding CBA for long-standing persistent AF (PeAF) are limited. We evaluated the efficacy and safety of CBA for long-standing PeAF compared to PeAF. Methods The study included 1484 patients with non-paroxysmal AF from Korean CBA registry data with follow-up of >12 months after de novo CBA. The primary outcome was recurrence of atrial tachyarrhythmias (ATs) of >= 30-s after a 3-month blanking period. Results A total of 367 PeAF (25%) and 1117 long-standing PeAF (75.3%) patients (mean age 61.99.6 years, 80% men) underwent de novo CBA. Compared to patients with PeAF, patients with long-standing PeAF had more heart failure, previous stroke or transient ischemic attack, chronic kidney disease, higher CHA(2)DS(2)-VASc score, and larger left atrium (LA). During a mean follow-up period of 15.1 +/- 10.9 months, ATs recurrence occurred in 41.4% of PeAF and 40.1% of long-standing PeAF. Multivariate analysis showed that female gender (hazard ratio [HR]: 1.31, p=0.01), larger LA >= 45mm (HR: 1.53, p<.001) and LA volume index >= 51mL/m(2) (HR: 1.77, p<0.001), and longer AF duration >= 5 years (HR: 1. 33, p=.003) were associated with ATs recurrence. After propensity score matching, larger LA was an independent factor for ATs recurrence. Conclusions During a long-term follow-up period after index CBA in patients with non-paroxysmal AF, ATs recurrence rate was similar between PeAF and long-standing PeAF. CBA might be an effective strategy as an initial rhythm control therapy regardless of AF type.