Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김민지 | * |
| dc.date.accessioned | 2024-05-16T16:30:05Z | - |
| dc.date.available | 2024-05-16T16:30:05Z | - |
| dc.date.issued | 2024 | * |
| dc.identifier.issn | 2234-7518 | * |
| dc.identifier.issn | 2005-372X | * |
| dc.identifier.other | OAK-35175 | * |
| dc.identifier.uri | https://dspace.ewha.ac.kr/handle/2015.oak/268188 | - |
| dc.description.abstract | Objective: To quantify the effects of midline-related landmark identification on midline deviation measurements in posteroanterior (PA) cephalograms using a cascaded convolutional neural network (CNN). Methods: A total of 2,903 PA cephalogram images obtained from 9 university hospitals were divided into training, internal validation, and test sets (n = 2,150, 376, and 377). As the gold standard, 2 orthodontic professors marked the bilateral landmarks, including the frontozygomatic suture point and latero-orbitale (LO), and the midline landmarks, including the crista galli, anterior nasal spine (ANS), upper dental midpoint (UDM), lower dental midpoint (LDM), and menton (Me). For the test, Examiner -1 and Examiner -2 (3 -year and 1 -year orthodontic residents) and the Cascaded -CNN models marked the landmarks. After point-to-point errors of landmark identification, the successful detection rate (SDR) and distance and direction of the midline landmark deviation from the midsagittal line (ANS -mid, UDM-mid, LDM-mid, and Me -mid) were measured, and statistical analysis was performed. Results: The cascaded -CNN algorithm showed a clinically acceptable level of point-to-point error (1.26 mm vs. 1.57 mm in Examiner -1 and 1.75 mm in Examiner -2). The average SDR within the 2 mm range was 83.2%, with high accuracy at the LO (right, 96.9%; left, 97.1%), and UDM (96.9%). The absolute measurement errors were less than 1 mm for ANSmid, UDM-mid, and LDM-mid compared with the gold standard. Conclusions: The cascaded -CNN model may be considered an effective tool for the auto -identification of midline landmarks and quantification of midline deviation in PA cephalograms of adult patients, regardless of variations in the image acquisition method. | * |
| dc.language | English | * |
| dc.publisher | KOREAN ASSOC ORTHODONTISTS | * |
| dc.subject | Artificial intelligence | * |
| dc.subject | Convolutional neural network | * |
| dc.subject | Posteroanterior cephalograms | * |
| dc.title | Accuracy of posteroanterior cephalogram landmarks and measurements identification using a cascaded convolutional neural network algorithm: A multicenter study | * |
| dc.type | Article | * |
| dc.relation.issue | 1 | * |
| dc.relation.volume | 54 | * |
| dc.relation.index | SCIE | * |
| dc.relation.index | SCOPUS | * |
| dc.relation.index | KCI | * |
| dc.relation.startpage | 48 | * |
| dc.relation.lastpage | 58 | * |
| dc.relation.journaltitle | KOREAN JOURNAL OF ORTHODONTICS | * |
| dc.identifier.doi | 10.4041/kjod23.075 | * |
| dc.identifier.wosid | WOS:001206796500004 | * |
| dc.identifier.scopusid | 2-s2.0-85184256156 | * |
| dc.author.google | Han, Sung-Hoon | * |
| dc.author.google | Lim, Jisup | * |
| dc.author.google | Kim, Jun-Sik | * |
| dc.author.google | Cho, Jin-Hyoung | * |
| dc.author.google | Hong, Mihee | * |
| dc.author.google | Kim, Minji | * |
| dc.author.google | Kim, Su -Jung | * |
| dc.author.google | Kim, Yoon-Ji | * |
| dc.author.google | Kim, Young Ho | * |
| dc.author.google | Lim, Sung-Hoon | * |
| dc.author.google | Sung, Sang Jin | * |
| dc.author.google | Kang, Kyung-Hwa | * |
| dc.author.google | Baek, Seung-Hak | * |
| dc.author.google | Choi, Sung -Kwon | * |
| dc.author.google | Kim, Namkug | * |
| dc.contributor.scopusid | 김민지(57201330607;58638186800) | * |
| dc.date.modifydate | 20261020102901 | * |