View : 153 Download: 0

Comparison of Obturation Quality of Different Filling Techniques in C-shaped canals

Title
Comparison of Obturation Quality of Different Filling Techniques in C-shaped canals
Other Titles
C형 근관에서 다양한 충전 방법에 따른 충전 품질 비교
Authors
배고운
Issue Date
2024
Department/Major
임상치의학대학원 임상치의학과근관치료수복학전공
Keywords
obturation quality, C-shaped canal, filling technique, ultrasonic activation
Publisher
이화여자대학교 임상치의학대학원
Degree
Master
Advisors
김예미
Abstract
Introduction : The object of this study was to compare the filling quality performed with sealer-based obturation technique (SBO) and continuous wave technique (CWT) in C‐shaped mandibular molars by micro-computed tomography (micro-CT). The effect of ultrasonic activation was investigated. Material and Methods : Thirty mandibular molar with C-shaped canals were studied and classified into three groups according to the filling methods: CWT group was a continuous wave technique; SBO group was a sealer-based obturation technique; and SBU (sealer based obturation with ultrasonic activation) group was the same method as SBO with the addition of ultrasonic activation. The teeth were scanned using micro-CT at 2 times; after preparation and after root canal filling. The volume of total voids, open porosity and closed porosity were measured. Data was analyzed using ANOVA and Tukey test. Results : The SBU group showed a significantly fewer void volume than the other two groups. In the apical third, SBU group showed a significantly lower mean percentage of total voids, compared with CWT. In the middle third, The SBU group showed a significantly fewer void volume than the other two groups and the percentage volume of voids associated with the CWT and SBO group was similar. There were no significant differences among the three obturation techniques in the coronal third. In all obturation techniques, open porosity was higher than closed porosity and open porosity showed similar results to total voids. Conclusion : The sealer based obturation with ultrasonic activation showed a fewer void volume in mandibular molars with C-shaped canal. Therefore, Sealer-based obturation with ultrasonic activation may improve filling quality of C-shaped mandibular molars with lower technique-sensitivity compared to Continuous wave technique.;본 연구에서는 C형 근관을 가진 하악 대구치에서 세가지 충전 기법, Continuous wave technique(CWT), Sealer based obturation(SBO), Sealer based obturation with ultrasonic activation(SBU) 로 충전하였을 때 충전의 질을 미세 컴퓨터 단층 촬영(micro-CT)을 이용하여 평가하고자 한다. C형 근관을 갖는 하악 대구치 30개를 준비하였으며, 근관성형 후 전체 근관 부피를 micro CT를 이용하여 측정하였다. 근관 부피에 따라 세 군으로 분류 후, 각각의 충전 방법에 따라 충전을 시행하였다. CWT 군은 AH plus 실러를 사용하여 Continuous wave technique 으로, SBO 군은 Endoseal MTA 사용하여 sealer based obturation 으로, SBU 군은 SBO와 동일한 방식에, 초음파 활성을 추가하였다. 근관 충전 후 micro CT로 공극의 부피를 측정하였다. 충전 방법에 따른 공극 비율을 ANOVA와 Tukey 테스트를 사용하여 분석하였다. SBU 그룹은 전체 근관에서 다른 두 그룹에 비해 유의하게 적은 공극 비율을 보였다. 근단부 1/3에서 SBU 그룹은 CWT에 비해 낮은 공극 비율을 보였다. 중간 1/3에서는 SBU 그룹이 다른 두 그룹에 비해 낮은 공극 비율을 보였으며, CWT와 SBO 그룹의 공극 비율은 비슷했다. 치관부 1/3 에서는 세 가지 충전방식 간 유의미한 차이가 없었다. 모든 충전방식에서 개방공극률(open porosity)은 폐쇄공극률(closed porosity)보다 높게 나타났으며, 개방공극률은 전체 공극률과 비슷한 결과를 보였다. C형 근관을 갖는 하악 대구치에서 초음파 활성화를 이용한 sealer based obturation 충전방식은 더 적은 공극비율을 보여주었다. C형 근관을 갖는 하악대구치에서 sealer based obturation이 초음파 활성과 함께 사용될 때 더 나은 충전의 질을 보일 수 있다.
Fulltext
Show the fulltext
Appears in Collections:
임상치의학대학원 > 근관치료수복학전공 > Theses_Master
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE