View : 386 Download: 63

Full metadata record

DC Field Value Language
dc.contributor.author성사현*
dc.date.accessioned2023-01-04T16:31:18Z-
dc.date.available2023-01-04T16:31:18Z-
dc.date.issued2022*
dc.identifier.issn2314-6133*
dc.identifier.issn2314-6141*
dc.identifier.otherOAK-32600*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/263034-
dc.description.abstractThe purpose of this study to explore strategies for reducing cement leakage during cement-augmented pedicle screw fixation, we compared the cement distribution patterns and biomechanical strengths of different types of cement-augmented fenestrated screws and traditional cement-augmented techniques. We compared five screw groups in this study: (1) Cannulated screws (Cann); (2) distal one-hole screws (D1); (3) distal two-hole screws (D2); (4) middle two-hole screws (M2); and (5) traditional screws with a traditional cement injection technique (Trad). The screws were inserted into cancellous bone blocks using a controlled, adequate cement injection pressure (1.6-2.0 kg), and an appropriate cement viscosity. Center to screw tip distance, three-dimensional distribution, and pull-out strength for cement were compared between groups. The average distance between the cement center and the screw tip was highest in the M2 group, suggesting a higher risk of cement leakage into the spinal canal. The Trad group had the highest migration distance in the z-axis, also reflecting a higher risk of leakage into the spinal canal. The D1 group had the highest pull-out strength (253 +/- 48.82 N and 797 +/- 58.31 N) in bone blocks representing different degrees of osteoporosis, and the D2 group had the second highest pull-out strength in the severe osteoporosis model. Overall, D1 screws appeared to be the best option for optimizing biomechanical function and minimizing the risk of cement leakage into the spinal canal in patients with osteoporotic bone undergoing spinal surgery.*
dc.languageEnglish*
dc.publisherHINDAWI LTD*
dc.titleBiomechanical Comparison and Three-Dimensional Analysis of Cement Distribution Patterns for Different Pedicle Screw Designs*
dc.typeArticle*
dc.relation.volume2022*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.journaltitleBIOMED RESEARCH INTERNATIONAL*
dc.identifier.doi10.1155/2022/8293524*
dc.identifier.wosidWOS:000877893900005*
dc.author.googleSung, Sahyun*
dc.author.googleKwon, Ji-Won*
dc.author.googlePark, Tae Hyun*
dc.author.googleLee, Soo-Bin*
dc.author.googleMoon, Seong-Hwan*
dc.author.googleLee, Byung Ho*
dc.contributor.scopusid성사현(57215587275)*
dc.date.modifydate20240309081000*
Appears in Collections:
의료원 > 의료원 > Journal papers
Files in This Item:
8293524.pdf(1.12 MB) Download
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE