View : 784 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author윤병호*
dc.date.accessioned2022-08-12T16:31:27Z-
dc.date.available2022-08-12T16:31:27Z-
dc.date.issued2022*
dc.identifier.issn0883-5403*
dc.identifier.issn1532-8406*
dc.identifier.otherOAK-32074*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/262435-
dc.description.abstractBackground: Highly cross-linked polyethylene (HXLPE) liners have been developed to address the wear -related problems associated with conventional polyethylene (CPE) such as osteolysis or aseptic loosening in total hip arthroplasty (THA). In this systematic meta-analysis, we compared the long-term efficacy in preventing radiological osteolysis and revision surgery between HXLPE and CPE. Methods: We included 14 studies that compared HXLPE and CPE reporting the incidence of wear-related complications with a minimum follow-up of 10 years. We investigated 5 wear-related complications: osteolysis, excessive wear, linear wear rate, revision surgery due to wear, and progress of osteolysis/aseptic loosening. We conducted a pair-wise meta-analysis to estimate odds ratio (OR) and a propor-tional meta-analysis to estimate the incidence of each complication. Results: Among 1,175 THAs, 220 osteolysis and 78 wear-related revisions were detected. The use of HXLPE reduced the risk of overall osteolysis (OR 0.30; P = .001), excessive wear (OR 0.10; P < .001), linear wear rate (weighted mean difference 0.09; P < .001), the risk of overall wear-related revisions (OR 0.06; P < .001), and revisions due to aseptic loosening (OR 0.23; P = .015). As per the proportional meta-analysis, the pooled prevalence of osteolysis, excessive wear, and the overall wear-related revision rate were 14%, 8%, and 3% in HXLPE and 25%, 33%, and 20% in CPE, respectively. Conclusion: The current evidence shows that HXLPE dramatically reduced the rate of osteolysis and wear-related revision surgery. However, as polyethylene wear and osteolysis still lead to revision surgery, ongoing clinical and retrieval studies are required to analyze long-term outcomes. (C) 2022 Elsevier Inc. All rights reserved.*
dc.languageEnglish*
dc.publisherCHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS*
dc.subjectcross-linked*
dc.subjecthip arthroplasty*
dc.subjectpolyethylene*
dc.subjectosteolysis*
dc.subjectrevision*
dc.subjectradiological wear*
dc.titleLong-Term Wear-Related Complications of Cross-Linked Versus Conventional Polyethylene After Total Hip Arthroplasty: A Meta-Analysis*
dc.typeReview*
dc.relation.issue11*
dc.relation.volume37*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage2308*
dc.relation.lastpage+*
dc.relation.journaltitleJOURNAL OF ARTHROPLASTY*
dc.identifier.doi10.1016/j.arth.2022.05.013*
dc.identifier.wosidWOS:000877670000031*
dc.identifier.scopusid2-s2.0-85131517398*
dc.author.googleYoon, Byung-Ho*
dc.author.googlePark, Jung -Wee*
dc.author.googleLee, Young-Kyun*
dc.author.googleKoo, Kyung-Hoi*
dc.author.googleChang, Chong Bum*
dc.contributor.scopusid윤병호(15078729100)*
dc.date.modifydate20260813140907*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode