View : 475 Download: 0

Reconstruction for plane-wave ultrasound imaging using modified U-Net-based beamformer

Title
Reconstruction for plane-wave ultrasound imaging using modified U-Net-based beamformer
Authors
Nguon L.S.Seo J.Seo K.Han Y.Park S.
Ewha Authors
박수현
SCOPUS Author ID
박수현scopus
Issue Date
2022
Journal Title
Computerized Medical Imaging and Graphics
ISSN
0895-6111JCR Link
Citation
Computerized Medical Imaging and Graphics vol. 98
Keywords
BeamformingCoherent plane-wave compoundingDeep learningDelay-and-sumPlane-wave ultrasound imagingReconstruction
Publisher
Elsevier Ltd
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
An image reconstruction method that can simultaneously provide high image quality and frame rate is necessary for diagnosis on cardiovascular imaging but is challenging for plane-wave ultrasound imaging. To overcome this challenge, an end-to-end ultrasound image reconstruction method is proposed for reconstructing a high-resolution B-mode image from radio frequency (RF) data. A modified U-Net architecture that adopts EfficientNet-B5 and U-Net as the encoder and decoder parts, respectively, is proposed as a deep learning beamformer. The training data comprise pairs of pre-beamformed RF data generated from random scatterers with random amplitudes and corresponding high-resolution target data generated from coherent plane-wave compounding (CPWC). To evaluate the performance of the proposed beamforming model, simulation and experimental data are used for various beamformers, such as delay-and-sum (DAS), CPWC, and other deep learning beamformers, including U-Net and EfficientNet-B0. Compared with single plane-wave imaging with DAS, the proposed beamforming model reduces the lateral full width at half maximum by 35% for simulation and 29.6% for experimental data and improves the contrast-to-noise ratio and peak signal-to-noise ratio, respectively, by 6.3 and 9.97 dB for simulation, 2.38 and 3.01 dB for experimental data, and 3.18 and 1.03 dB for in vivo data. Furthermore, the computational complexity of the proposed beamforming model is four times less than that of the U-Net beamformer. The study results demonstrate that the proposed ultrasound image reconstruction method employing a deep learning beamformer, trained by the RF data from scatterers, can reconstruct a high-resolution image with a high frame rate for single plane-wave ultrasound imaging. © 2022 Elsevier Ltd
DOI
10.1016/j.compmedimag.2022.102073
Appears in Collections:
공과대학 > 전자전기공학전공 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE