View : 987 Download: 289

Full metadata record

DC Field Value Language
dc.contributor.author이용현*
dc.date.accessioned2020-12-24T16:30:19Z-
dc.date.available2020-12-24T16:30:19Z-
dc.date.issued2020*
dc.identifier.issn1838-7640*
dc.identifier.otherOAK-28486*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/255867-
dc.description.abstractRationale: Magnetic relaxation switching (MRSw) induced by target-triggered aggregation or dissociation of superparamagnetic iron oxide nanoparticles (SPIONs) have been utilized for detection of diverse biomarkers. However, an MRSw-based biosensor for reactive oxygen species (ROS) has never been documented. Methods: To this end, we constructed a biosensor for ROS detection based on PEGylated bilirubin (PEG-BR)-coated SPIONs (PEG-BR@SPIONs) that were prepared by simple sonication via ligand exchange. In addition, near infra-red (NIR) fluorescent dye was loaded onto PEG-BR@SPIONs as a secondary option for fluorescence-based ROS detection. Results: PEG-BR@SPIONs showed high colloidal stability under physiological conditions, but upon exposure to the model ROS, NaOCl, in vitro, they aggregated, causing a decrease in signal intensity in T2-weighted MR images. Furthermore, ROS-responsive PEG-BR@SPIONs were taken up by lipopolysaccharide (LPS)-activated macrophages to a much greater extent than ROS-unresponsive control nanoparticles (PEG-DSPE@SPIONs). In a sepsis-mimetic clinical setting, PEG-BR@SPIONs were able to directly detect the concentrations of ROS in whole blood samples through a clear change in T2 MR signals and a 'turn-on' signal of fluorescence. Conclusions: These findings suggest that PEG-BR@SPIONs have the potential as a new type of dual mode (MRSw-based and fluorescence-based) biosensors for ROS detection and could be used to diagnose many diseases associated with ROS overproduction.*
dc.languageEnglish*
dc.publisherIVYSPRING INT PUBL*
dc.subjectBilirubin nanoparticles*
dc.subjectBiosensors*
dc.subjectIron oxide nanoparticles*
dc.subjectMagnetic relaxation switching*
dc.subjectReactive oxygen species*
dc.titlePEGylated Bilirubin-coated Iron Oxide Nanoparticles as a Biosensor for Magnetic Relaxation Switching-based ROS Detection in Whole Blood*
dc.typeArticle*
dc.relation.issue5*
dc.relation.volume10*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage1997*
dc.relation.lastpage2007*
dc.relation.journaltitleTHERANOSTICS*
dc.identifier.doi10.7150/thno.39662*
dc.identifier.wosidWOS:000508008300002*
dc.identifier.scopusid2-s2.0-85078221743*
dc.author.googleLee, Dong Yun*
dc.author.googleKang, Sukmo*
dc.author.googleLee, Yonghyun*
dc.author.googleKim, Jin Yong*
dc.author.googleYoo, Dohyun*
dc.author.googleJung, Wonsik*
dc.author.googleLee, Soyoung*
dc.author.googleJeong, Yong Yeon*
dc.author.googleLee, Kwangyeol*
dc.author.googleJon, Sangyong*
dc.contributor.scopusid이용현(38561637800)*
dc.date.modifydate20260811150107*
Appears in Collections:
약학대학 > 약학과 > Journal papers
Files in This Item:
v10p1997.pdf(1.61 MB) Download
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE