View : 949 Download: 357

Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva

Title
Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva
Authors
Song, Jihu; Kim, Minji
Ewha Authors
김민지
SCOPUS Author ID
김민지scopusscopus
Issue Date
2020
Journal Title
BIOMED RESEARCH INTERNATIONAL
ISSN
2314-6133JCR Link

2314-6141JCR Link
Citation
BIOMED RESEARCH INTERNATIONAL vol. 2020
Publisher
HINDAWI LTD
Indexed
SCIE; SCOPUS WOS
Document Type
Article
Abstract
Aim. This study aims to evaluate the accuracy of scanned images of 4 clinically used intraoral scanners (CS3600, i500, Trios3, Omnicam) when scanning the surface of full arch models with various kinds of orthodontic brackets in the presence of artificial saliva. Materials and Methods. Four study models were prepared; bonded with ceramic, metal, and resin brackets, respectively, and without brackets. Reference images were taken by scanning the models with an industrial scanner. Study models were then applied with an artificial saliva and scanned 10 times, respectively, with the above 4 intraoral scanners. All images were converted to STL file format and analyzed with 3D analysis software. By superimposing with the reference images, mean maximum discrepancy values and mean discrepancy values were collected and compared. For statistical analysis, two-way ANOVA was used. Results. Omnicam (1.247 +/- 0.255) showed higher mean maximum discrepancy values. CS3600 (0.758 +/- 0.170), Trios3 (0.854 +/- 0.166), and i500 (0.975 +/- 0.172) performed relatively favourably. Resin (1.119 +/- 0.255) and metal (1.086 +/- 0.132) brackets showed higher mean maximum discrepancy values. Nonbracket (0.776 +/- 0.250) and ceramic bracket (0.853 +/- 0.269) models generally showed lower mean maximum discrepancy values in studied scanners. In mean discrepancy values, the difference between scanners was not statistically significant whereas among brackets, resin bracketed models (0.093 +/- 0.142) showed the highest value. Conclusion. Intraoral scanners and brackets had significant influences on the scanned images with application of artificial saliva on the study models. It may be expected to have similar outcomes in an intraoral environment. Some data showed the discrepancy values up to about 1.5 mm that would require more caution in using intraoral scanners for production of detailed appliances and records.
DOI
10.1155/2020/2920804
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
Accuracy on Scanned Images.pdf(2.49 MB) Download
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE