View : 565 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author박준범*
dc.date.accessioned2019-11-22T16:30:03Z-
dc.date.available2019-11-22T16:30:03Z-
dc.date.issued2015*
dc.identifier.issn0018-9294*
dc.identifier.issn1558-2531*
dc.identifier.otherOAK-25732*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/252152-
dc.description.abstractThe heart characteristic length, the inverse of conduction velocity (CV), and the inverse of the refractory period are known to determine vulnerability to cardiac fibrillation (fibrillation number, FibN) in in silico or ex vivo models. The purpose of this study was to validate the accuracy of FibN through in silico atrial modeling and to evaluate its clinical application in patients with atrial fibrillation (AF) who had undergone radiofrequency catheter ablation. We compared the maintenance duration of AF at various FibN(AF) values using in silico bidomain atrial modeling. Among 60 patients (72% male, 54 +/- 13 years old, 82% with paroxysmal AF) who underwent circumferential pulmonary vein isolation (CPVI) for AF rhythm control, we examined the relationship between FibN(AF) and postprocedural AF inducibility or induction pacing cycle length (iPCL). Clinical FibN(AF) was calculated using left atrium (LA) dimension (echocardiogram), the inverse of CV, and the inverse of the atrial effective refractory periods measured at proximal and distal coronary sinus. In silico simulation found a positive correlation between AF maintenance duration and FibN(AF) (R = 0.90, p < 0.001). After clinical CPVI, FibN(AF) (0.296 +/- 0.038 versus 0.192 +/- 0.028, p < 0.001) was significantly higher in patients with postprocedural AF inducibility (n = 41) than in those without (n = 19). Among 41 patients with postprocedural AF inducibility, FibN(AF) (P = 0.935, p < 0.001) had excellent correlations with induction pacing cycle length. FibN(AF), based on LA mass and wavelength, correlates well with AF maintenance in computational modeling and clinical AF inducibility after CPVI.*
dc.languageEnglish*
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC*
dc.subjectArrhythmogenecity*
dc.subjectAtrial fibrillation (AF)*
dc.subjectcritical mass*
dc.subjectparameter*
dc.subjectwavelength*
dc.titleFibrillation Number Based on Wavelength and Critical Mass in Patients Who Underwent Radiofrequency Catheter Ablation for Atrial Fibrillation*
dc.typeArticle*
dc.relation.issue2*
dc.relation.volume62*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage673*
dc.relation.lastpage679*
dc.relation.journaltitleIEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING*
dc.identifier.doi10.1109/TBME.2014.2363669*
dc.identifier.wosidWOS:000348297000030*
dc.author.googleHwang, Minki*
dc.author.googlePark, Junbeum*
dc.author.googleLee, Young-Seon*
dc.author.googlePark, Jae Hyung*
dc.author.googleChoi, Sung Hwan*
dc.author.googleShim, Eun Bo*
dc.author.googlePak, Hui-Nam*
dc.contributor.scopusid박준범(55131469900)*
dc.date.modifydate20240429132147*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE