View : 1045 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author양세정-
dc.date.accessioned2018-11-16T16:30:16Z-
dc.date.available2018-11-16T16:30:16Z-
dc.date.issued2018-
dc.identifier.issn1864-063X-
dc.identifier.issn1864-0648-
dc.identifier.otherOAK-23442-
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/246597-
dc.description.abstractCutaneous radiation injury (CRI) is a skin injury caused by high-dose exposure of ionizing radiation (IR). For proper treatment, early detection of CRI before clinical symptoms is important. Optical microscopic techniques such as reflectance confocal microscopy (RCM) and 2-photon microscopy (TPM) have been tested as the early diagnosis method by detecting cellular changes. In this study, RCM and TPM were compared in the detection of cellular changes caused by CRI in an in vivo mouse model. CRI was induced on the mouse hindlimb skin with various IR doses and the injured skin regions were imaged longitudinally by both modalities until the onset of clinical symptoms. Both RCM and TPM detected the changes of epidermal cells and sebaceous glands before clinical symptoms in different optical contrasts. RCM detected changes of cell morphology and scattering property based on light reflection. TPM detected detail changes of cellular structures based on autofluorescence of cells. Since both RCM and TPM were sensitive to the early stage CRI by using different contrasts, the optimal method for clinical CRI diagnosis could be either individual methods or their combination.-
dc.languageEnglish-
dc.publisherWILEY-V C H VERLAG GMBH-
dc.subjectan in vivo mouse model-
dc.subjectcutaneous radiation injury-
dc.subjectearly detection-
dc.subjectreflectance confocal microscopy-
dc.subject2-photon microscopy-
dc.titleComparison between reflectance confocal microscopy and 2-photon microscopy in early detection of cutaneous radiation injury in a mouse model in vivo-
dc.typeArticle-
dc.relation.issue10-
dc.relation.volume11-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.journaltitleJOURNAL OF BIOPHOTONICS-
dc.identifier.doi10.1002/jbio.201700337-
dc.identifier.wosidWOS:000446666000004-
dc.identifier.scopusid2-s2.0-85050498087-
dc.author.googleJang, Won Hyuk-
dc.author.googleKwon, Soonjae-
dc.author.googleShim, Sehwan-
dc.author.googleJang, Won-Suk-
dc.author.googleMyung, Jae Kyung-
dc.author.googleYang, Sejung-
dc.author.googlePark, Sunhoo-
dc.author.googleKim, Ki Hean-
dc.contributor.scopusid양세정(57215371253)-
dc.date.modifydate20220105111357-
Appears in Collections:
연구기관 > 예술과학융합연구소 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE