View : 822 Download: 0

Image quality at synthetic brain magnetic resonance imaging in children

Title
Image quality at synthetic brain magnetic resonance imaging in children
Authors
Lee S.M.Choi Y.H.Cheon J.-E.Kim I.-O.Cho S.H.Kim W.H.Kim H.J.Cho H.-H.You S.-K.Park S.-H.Hwang M.J.
Ewha Authors
조현혜
Issue Date
2017
Journal Title
Pediatric Radiology
ISSN
0301-0449JCR Link
Citation
Pediatric Radiology vol. 47, no. 12, pp. 1638 - 1647
Keywords
BrainChildrenImage qualityMagnetic resonance imagingMulti-echo multi-delay magnetic resonance imagingNeonatesSynthetic imaging
Publisher
Springer Verlag
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Background: The clinical application of the multi-echo, multi-delay technique of synthetic magnetic resonance imaging (MRI) generates multiple sequences in a single acquisition but has mainly been used in adults. Objective: To evaluate the image quality of synthetic brain MR in children compared with that of conventional images. Materials and methods: Twenty-nine children (median age: 6 years, range: 0–16 years) underwent synthetic and conventional imaging. Synthetic (T2-weighted, T1-weighted and fluid-attenuated inversion recovery [FLAIR]) images with settings matching those of the conventional images were generated. The overall image quality, gray/white matter differentiation, lesion conspicuity and image degradations were rated on a 5-point scale. The relative contrasts were assessed quantitatively and acquisition times for the two imaging techniques were compared. Results: Synthetic images were inferior due to more pronounced image degradations; however, there were no significant differences for T1- and T2-weighted images in children <2 years old. The quality of T1- and T2-weighted images were within the diagnostically acceptable range. FLAIR images showed greatly reduced quality. Gray/white matter differentiation was comparable or better in synthetic T1- and T2-weighted images, but poorer in FLAIR images. There was no effect on lesion conspicuity. Synthetic images had equal or greater relative contrast. Acquisition time was approximately two-thirds of that for conventional sequences. Conclusion: Synthetic T1- and T2-weighted images were diagnostically acceptable, but synthetic FLAIR images were not. Lesion conspicuity and gray/white matter differentiation were comparable to conventional MRI. © 2017, Springer-Verlag Berlin Heidelberg.
DOI
10.1007/s00247-017-3913-y
Appears in Collections:
의료원 > 의료원 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE