View : 580 Download: 0

Development of LC/MS/MS assay for the determination of 5-ethyl-2-{5-[4-(2-hydroxyethyl)piperazine-1-sulfonyl]-2-propoxyphenyl}-7-propyl-3,5-dihydropyrrolo[3,2-d]pyrimidin-4-one (SK3530) in human plasma: application to a clinical pharmacokinetic study

Title
Development of LC/MS/MS assay for the determination of 5-ethyl-2-{5-[4-(2-hydroxyethyl)piperazine-1-sulfonyl]-2-propoxyphenyl}-7-propyl-3,5-dihydropyrrolo[3,2-d]pyrimidin-4-one (SK3530) in human plasma: application to a clinical pharmacokinetic study
Authors
Shin B.S.Hu S.K.Kim J.Oh J.G.Youn W.-N.Lee B.Um K.A.Kim D.-K.Lee J.Y.Yoo S.D.
Ewha Authors
김대기
SCOPUS Author ID
김대기scopus
Issue Date
2007
Journal Title
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085JCR Link
Citation
Journal of Pharmaceutical and Biomedical Analysis vol. 45, no. 1, pp. 176 - 184
Indexed
SCI; SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
5-Ethyl-2-{5-[4-(2-hydroxyethyl)piperazine-1-sulfonyl]-2-propoxyphenyl}-7-propyl-3,5-dihydropyrrolo[3,2-d]pyrimidin-4-one (SK3530) is a new phosphodiesterase type-5 inhibitor currently undergoing a Phase III investigation for the treatment of male erectile dysfunction. This study first describes a rapid and sensitive LC/MS/MS assay method for the quantification of SK3530 and its major metabolite, SK3541, in human plasma. The assay was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), accuracy, and precision. The multiple reaction monitoring was based on the transition of m/z = 532.5 → 99.1 for SK3530, 488.6 → 295.5 for SK3541, and 520.3 → 99.1 for SK3304 (internal standard). The assay utilized a single liquid-liquid extraction and isocratic elution, and the LLOQ was 1 ng/ml using 0.2 ml human plasma. The assay was linear over a range from 1 to 1000 ng/ml for both SK3530 and SK3541, with correlation coefficients >0.9999. The mean intra- and inter-day assay accuracy ranged from 94.7 to 101.6% and 96.8 to 101.1% for SK3530 and 92.6-105.7% and 97.4-107.8% for SK3541, respectively. The mean intra- and inter-day precision was between 7.2-12.1% and 5.7-7.4% for SK3530 and 4.6-13.2% and 5.0-14.1% for SK3541, respectively. The developed assay was applied to a clinical pharmacokinetic study after oral administration of SK3530 in healthy male volunteers (dose 100 mg). © 2007 Elsevier B.V. All rights reserved.
DOI
10.1016/j.jpba.2007.06.021
Appears in Collections:
약학대학 > 약학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE