View : 637 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author김영후*
dc.contributor.author김준식*
dc.contributor.author박장원*
dc.date.accessioned2016-12-28T02:12:28Z-
dc.date.available2016-12-28T02:12:28Z-
dc.date.issued2016*
dc.identifier.issn0883-5403*
dc.identifier.issn1532-8406*
dc.identifier.otherOAK-19783*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/233295-
dc.description.abstractBackground: The purpose of this retrospective study was to determine the clinical and radiographic results, prevalence of polyethylene wear and osteolysis, and fracture of alumina delta ceramic femoral head or highly crosslinked, remelted polyethylene (HXLPE) liner associated with the use of alumina delta ceramic femoral head-on-HXLPE bearing in cementless total hip arthroplasty in patients younger than 50 years. Methods: We reviewed the cases of 119 patients (130 hips) who underwent a cementless total hip arthroplasty using alumina delta ceramic-on-HXLPE bearing when they were 50 years or younger at the time of surgery. The most common diagnoses were osteonecrosis (51%) and osteoarthritis secondary to developmental dysplastic hip (39%). Osteolysis and polyethylene wear rates were evaluated with use of radiography and computed tomography. In addition, prevalence of fracture of alumina delta ceramic head and polyethylene line was documented. The mean follow-up was 8.3 years (range, 7-9 years). Results: The mean Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 94 points, 14 points, and 8.1 points, respectively, at the final follow-up. No patient had thigh pain. All acetabular components and all but one femoral components were well fixed. The mean annual penetration rate of femoral head was 0.022 +/- 0.003 mm/year. No hip had osteolysis or ceramic head or HXLPE liner fracture. Conclusion: Our average 8.3-year results with the use of alumina delta ceramic-on-HXLPE bearing in the patients younger than 50 years suggest that cementless acetabular and femoral components provide a high survival rate without evidence of osteolysis or ceramic head or AXLPE liner fracture. (C) 2016 Elsevier Inc. All rights reserved.*
dc.languageEnglish*
dc.publisherCHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS*
dc.subjectcementless total hip arthroplasty*
dc.subjectalumina delta-on-alumina-delta*
dc.subjectalumina delta-on-highly crosslinked*
dc.subjectpolyethylene*
dc.subjectyoung patients*
dc.subjectpolyethylene wear*
dc.subjectosteolysis*
dc.titleAlumina Delta-on-Highly Crosslinked-Remelted Polyethylene Bearing in Cementless Total Hip Arthroplasty in Patients Younger than 50 Years*
dc.typeArticle*
dc.relation.issue12*
dc.relation.volume31*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage2800*
dc.relation.lastpage2804*
dc.relation.journaltitleJOURNAL OF ARTHROPLASTY*
dc.identifier.doi10.1016/j.arth.2016.05.020*
dc.identifier.wosidWOS:000392622100028*
dc.identifier.scopusid2-s2.0-84995676769*
dc.author.googleKim, Young-Hoo*
dc.author.googlePark, Jang-Won*
dc.author.googleKim, Jun-Shik*
dc.contributor.scopusid김영후(23481974900)*
dc.contributor.scopusid김준식(8516905600;57191682200)*
dc.contributor.scopusid박장원(55645949000)*
dc.date.modifydate20240220120149*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE