View : 913 Download: 0

The effects of the trendelenburg position and intrathoracic pressure on the subclavian cross-sectional area and distance from the subclavian vein to pleura in anesthetized patients

Title
The effects of the trendelenburg position and intrathoracic pressure on the subclavian cross-sectional area and distance from the subclavian vein to pleura in anesthetized patients
Authors
Kwon M.-Y.Lee E.-K.Kang H.-J.Kil H.-Y.Jang K.-H.Koo M.-S.Lee G.-H.Lee M.-A.Kim T.-Y.
Ewha Authors
이은경
SCOPUS Author ID
이은경scopusscopus
Issue Date
2013
Journal Title
Anesthesia and Analgesia
ISSN
0003-2999JCR Link
Citation
Anesthesia and Analgesia vol. 117, no. 1, pp. 114 - 118
Indexed
SCI; SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
BACKGROUND: The effects of maneuvers to increase intrathoracic pressure and of Trendelenburg position on the cross-sectional area (CSA) of the subclavian vein (SCV) and the relationship between the SCV and adjacent structures have not been investigated. METHODS: In ultrasonography-guided SCV catheterization (N = 30), the CSA of the SCV and the distance between the SCV and pleura (D SCV-pleura) were determined during 10-second airway opening, and 10-second positive inspiratory hold with 20 cm H2O in the supine position (S-0, and S-20) and the 10° Trendelenburg position (T-0, and T-20). In addition to a statistical significance of P < 0.05, CSA and D SCV-pleura differences of ≥15% were defined as clinically relevant changes. RESULTS: CSA (mean [95% confidence interval]) in S-20, T-0, and T-20 (1.02 [0.95-1.14] cm2, 1.04 [0.95-1.15] cm2, and 1.14 [1.04-1.24] cm2, respectively) was significantly larger than a CSA in S-0 (0.93 [0.86-1.00] cm2, all P < 0.001). However, only the increase of CSA in T-20 vs S-0 (0.21 cm2, 23.2%) was clinically meaningful (≥15%). The number of patients who showed CSA increase ≥15% was more in S-0 to T-20 (57%) compared with those in S-0 to S-20 (23%) and S-0 to T-0 (27%). DSCV-pleura measurements (mean) in S-20 and T-20 (0.61 and 0.60 cm) were significantly shorter than those in S-0 (0.70 cm, all P < 0.001), but the reductions of DSCV-pleura were not clinically meaningful (≥15%). CONCLUSIONS: The combined application of inspiratory hold and Trendelenburg position provided a greater and more relevant degree of CSA increase without compromising DSCV-pleura, which may facilitate SCV catheterization. Further investigations are needed to determine whether these results affect the success rate of catheterization and the risk of procedural injury. Copyright © 2013 International Anesthesia Research Society.
DOI
10.1213/ANE.0b013e3182860e3c
Appears in Collections:
자연과학대학 > 통계학전공 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE