View : 858 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author전윤식-
dc.date.accessioned2016-08-28T12:08:55Z-
dc.date.available2016-08-28T12:08:55Z-
dc.date.issued2011-
dc.identifier.issn0889-5406-
dc.identifier.otherOAK-7743-
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/221756-
dc.description.abstractIntroduction: Our objective was to evaluate the factors that affect effective torque control during en-masse incisor and canine retraction when using partially osseointegrated C-implants (Cimplant, Seoul, Korea) as the exclusive source of anchorage without posterior bonded or banded appliances. Methods: Base models were constructed from a dental study model. No brackets or bands were placed on the maxillary posterior dentition during retraction. The working archwire was modeled by using a 3-dimensional beam element (ANSYS beam 4, Swanson Analysis System, Canonsburg, Pa) with a cross section of 0.016 × 0.022-in stainless steel. Different heights of anterior retraction hooks and different degrees of gable bends were applied to the working utility archwire that was placed into the 0.8-mm diameter hole of the C-implant to generate anterior torque on the anterior segment of the teeth. The amount of tooth displacement after finite element analysis was exaggerated 70 times and compared with tooth-axis graphs of the central and lateral incisors and the canine. Results: The height of the anterior retraction hook and the degree of the gable bend had a combined effect on the labial crown torque applied to the incisors during en-masse retraction. By using 30° gable bends and the longest hook, lingual root movement of the 6 anterior teeth occurred. By using 20° gable bends, the 6 anterior teeth showed a translation tendency during retraction. Conclusions: Three-dimensional en-masse retraction of the 6 anterior teeth can be accomplished by using partially osseointegrated C-implants as the only source of anchorage, gable bends, and a long retraction hook (biocreative therapy type I technique). Copyright © 2011 by the American Association of Orthodontists.-
dc.languageEnglish-
dc.titleFactors controlling anterior torque during C-implant-dependent en-masse retraction without posterior appliances-
dc.typeArticle-
dc.relation.issue1-
dc.relation.volume140-
dc.relation.indexSCI-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.startpage72-
dc.relation.lastpage80-
dc.relation.journaltitleAmerican Journal of Orthodontics and Dentofacial Orthopedics-
dc.identifier.doi10.1016/j.ajodo.2009.09.026-
dc.identifier.wosidWOS:000292304100027-
dc.identifier.scopusid2-s2.0-79960023060-
dc.author.googleMo S.-S.-
dc.author.googleKim S.-H.-
dc.author.googleSung S.-J.-
dc.author.googleChung K.-R.-
dc.author.googleChun Y.-S.-
dc.author.googleKook Y.-A.-
dc.author.googleNelson G.-
dc.contributor.scopusid전윤식(7202638291)-
dc.date.modifydate20210301081004-
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE