View : 639 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author김용표*
dc.date.accessioned2016-08-27T04:08:27Z-
dc.date.available2016-08-27T04:08:27Z-
dc.date.issued2016*
dc.identifier.issn0039-9140*
dc.identifier.issn1873-3573*
dc.identifier.otherOAK-15923*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/217769-
dc.description.abstractAn analytical method was developed for the identification and quantification of seven volatile n-nitrosamines (n-nitrosodimethylamine [NDMA], n-nitrosoethylmethylamine [NMEA], n-nitrosodiethylamine [NDEA], n-nitrosodipropylamine [NDPA], n-nitrosodibutylamine [NDBA], n-nitrosopiperidine [NPIP], and n-nitrosopyrrolidine [NPYRD]) in water insoluble cream type cosmetics. It was found that the head space-solid phase microextraction (HS-SPME) was suitable for extraction, clean up, and pre-concentration of n-nitrosamines in the cream type samples so its optimal conditions were investigated. Identification and quantification of n-nitrosamines using single quadrupole gas chromatography/mass spectrometry (GC/MS) in chemical ionization (CI) mode were carried out with accurate mass measurements. Their accurate masses of protonated molecular ions were obtained within 10 mDa of the theoretical masses when sufficiently high signal was acquired from the unique calibration method using mass and isotope accuracy. For the method validation of quantification, spiking experiments were carried out to determine the linearity, recovery, and method detection limit (MDL) using three deuterated internal standards. The average recovery was 79% within 20% relative standard deviation (RSD) at the concentration of 50 ng/g. MDLs ranged from 0.46 ng/g to 36.54 ng/g, which was satisfactory for the directive limit of 50 ng/g proposed by the European Commission (EC). As a result, it was concluded that the method could be provided for the accurate mass screening, confirmation, and quantification of n-nitrosamines when applied to cosmetic inspection. (C) 2015 Elsevier B.V. All rights reserved.*
dc.languageEnglish*
dc.publisherELSEVIER SCIENCE BV*
dc.subjectN-nitrosamines*
dc.subjectCosmetics*
dc.subjectGas chromatography/Chemical Ionization-Mass Spectrometry (GC/CI-MS)*
dc.subjectHead space-solid phase microextraction (HS-SPME)*
dc.subjectAccurate mass*
dc.titleIdentification and quantification of seven volatile n-nitrosamines in cosmetics using gas chromatography/chemical ionization-mass spectrometry coupled with head space-solid phase microextraction*
dc.typeArticle*
dc.relation.volume148*
dc.relation.indexSCI*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage69*
dc.relation.lastpage74*
dc.relation.journaltitleTALANTA*
dc.identifier.doi10.1016/j.talanta.2015.10.045*
dc.identifier.wosidWOS:000366786400010*
dc.identifier.scopusid2-s2.0-84946423105*
dc.author.googleChoi, Na Rae*
dc.author.googleKim, Yong Pyo*
dc.author.googleJi, Won Hyun*
dc.author.googleHwang, Geum-Sook*
dc.author.googleAhn, Yun Gyong*
dc.contributor.scopusid김용표(8721787200)*
dc.date.modifydate20240415142127*
Appears in Collections:
공과대학 > 화공신소재공학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE