View : 730 Download: 0
Development of a New Metal Artifact Reduction Algorithm by Using an Edge Preserving Method for CBCT Imaging
- Title
- Development of a New Metal Artifact Reduction Algorithm by Using an Edge Preserving Method for CBCT Imaging
- Authors
- Kim, Juhye; Nam, Haewon; Lee, Rena
- Ewha Authors
- 이레나
- SCOPUS Author ID
- 이레나
- Issue Date
- 2015
- Journal Title
- JOURNAL OF THE KOREAN PHYSICAL SOCIETY
- ISSN
- 0374-4884
1976-8524
- Citation
- JOURNAL OF THE KOREAN PHYSICAL SOCIETY vol. 67, no. 1, pp. 180 - 188
- Keywords
- MAR algorithm; Metal artifact reduction; Image reconstruction
- Publisher
- KOREAN PHYSICAL SOC
- Indexed
- SCI; SCIE; SCOPUS; KCI
- Document Type
- Article
- Abstract
- CT (computed tomography) images, metal materials such as tooth supplements or surgical clips can cause metal artifact and degrade image quality. In severe cases, this may lead to misdiagnosis. In this research, we developed a new MAR (metal artifact reduction) algorithm by using an edge preserving filter and the MATLAB program (Mathworks, version R2012a). The proposed algorithm consists of 6 steps: image reconstruction from projection data, metal segmentation, forward projection, interpolation, applied edge preserving smoothing filter, and new image reconstruction. For an evaluation of the proposed algorithm, we obtained both numerical simulation data and data for a Rando phantom. In the numerical simulation data, four metal regions were added into the Shepp Logan phantom for metal artifacts. The projection data of the metal-inserted Rando phantom were obtained by using a prototype CBCT scanner manufactured by medical engineering and medical physics (MEMP) laboratory research group in medical science at Ewha Womans University. After these had been adopted the proposed algorithm was performed, and the result were compared with the original image (with metal artifact without correction) and with a corrected image based on linear interpolation. Both visual and quantitative evaluations were done. Compared with the original image with metal artifacts and with the image corrected by using linear interpolation, both the numerical and the experimental phantom data demonstrated that the proposed algorithm reduced the metal artifact. In conclusion, the evaluation in this research showed that the proposed algorithm outperformed the interpolation based MAR algorithm. If an optimization and a stability evaluation of the proposed algorithm can be performed, the developed algorithm is expected to be an effective tool for eliminating metal artifacts even in commercial CT systems.
- DOI
- 10.3938/jkps.67.180
- Appears in Collections:
- 의과대학 > 의학과 > Journal papers
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML