<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <title>DSpace Collection:</title>
  <link rel="alternate" href="https://dspace.ewha.ac.kr/handle/2015.oak/239892" />
  <subtitle />
  <id>https://dspace.ewha.ac.kr/handle/2015.oak/239892</id>
  <updated>2026-11-25T02:07:20Z</updated>
  <dc:date>2026-11-25T02:07:20Z</dc:date>
  <entry>
    <title>Addressing Challenges in Deep Learning-Based Diagnosis  for Pancreatic Cancer and Bile Duct Obstruction</title>
    <link rel="alternate" href="https://dspace.ewha.ac.kr/handle/2015.oak/276624" />
    <author>
      <name>Thoi, Do Kieu Trang</name>
    </author>
    <id>https://dspace.ewha.ac.kr/handle/2015.oak/276624</id>
    <updated>2026-11-24T16:31:20Z</updated>
    <published>2024-01-01T00:00:00Z</published>
    <summary type="text">Title: Addressing Challenges in Deep Learning-Based Diagnosis  for Pancreatic Cancer and Bile Duct Obstruction
Ewha Authors: Thoi, Do Kieu Trang
Abstract: In this comprehensive study, two distinct challenges in medical imaging diagnosis were addressed using deep learning techniques.&#xD;
Part 1: Invasive pancreatic cancer diagnosis in endoscopic ultrasound images leveraging translation models.&#xD;
In guiding treatment decisions for pancreatic cancer, assessing vascular invasion is critical, particularly for determining resectability. Deep learning techniques have demonstrated potential for diagnosing vascular invasion through the analysis of pancreatic endoscopic ultrasound (EUS) images. However, challenges arise when dealing with multicenter data sources and imbalanced datasets, which may affect the model performance. EUS images were collected from 170 patients with diagnosed pancreatic cancer at three endoscopy centers using various ultrasound systems. To diagnose vascular invasion while mitigating data variation, feature and image translation models were utilized to effectively align the source and target domains. An image translation model was utilized in the proposed approach (multicenter transfer learning (MCTL)) by employing CycleGAN and customized weighted loss classification models. The performance was compared with a feature translation model (multicenter domain adaptation (MCDA)) and widely accepted baseline classification models. The translation models compensated for distinctive data-specific features and improved the models for classifying vascular invasion. Although the feature translation model proved effective, its applicability was limited across different datasets. The proposed MCTL approach showed superior classification performance with accuracy improvements of 26.79%, 67.26%, and 50.91% over the baseline model and 17.86%, 48.81%, and 42.50% over the MCDA model for the three different imbalanced datasets. This research utilized a deep learning methodology to improve the identification of vascular invasion in pancreatic cancer through the analysis of EUS images from multiple centers and addressed the issue of data imbalance. &#xD;
Part 2: Multimodal deep learning-based diagnosis of extrahepatic common bile duct obstruction using MRCP images and clinical parameters.&#xD;
Magnetic resonance cholangiopancreatography (MRCP) is a noninvasive technique used for the diagnosis of extrahepatic common bile duct obstruction (EHBDO). However, its interpretation is laborious. This study aimed to devise a classification pipeline that automatically assists radiologists in diagnosing EHBDO by utilizing multimodal data such as MRCP images and clinical parameters. This study included 465 patients. Object detection was employed to enhance the common bile duct (CBD) region from MRCP images. Clinical parameters were collected from patients, compensated for missing values by imputation, and subjected to statistical tests. Using a single modality (clinical parameters or MRCP images), machine and deep learning approaches evaluated the diagnostic capabilities of each modality for detecting obstructions. To diagnose CBD obstruction and malignancy, a deep learning approach combining features from both MRCP images and clinical parameters was proposed. A weighted loss function addressing variations in importance of features was applied to each modality. The proposed deep learning model demonstrated superior performance compared to the use of a single modality. It achieved notable overall accuracy, AUC score, sensitivity, and specificity rates of 89.8%, 90.4%, 81.8%, 95.7%, for detecting obstruction and 77.0%, 82.5%, 67.2%, 91.2%, for identification of malignancy, respectively.&#xD;
Overall, this study showcases the potential of deep learning methodologies to improve diagnostic accuracy and efficiency in medical imaging.;본 연구에서는 딥러닝 기술을 사용하여 의료 영상 진단의 두 가지 과제를 해결했다. 첫 번째로 변환 모델을 활용한 내시경 초음파 영상의 췌장암 진단 방법을 연구했다. 췌장암 치료 결정을 내릴 때 혈관 침범을 평가하는 것은 수술에서의 절제 가능성을 결정하는 데 중요하다. 딥러닝 기술로 췌장 내시경 초음파(EUS) 영상 분석을 통해 혈관 침범을 진단할 수 있는 가능성을 입증했다. 연구에 사용한 데이터는 다중 센터에서 획득한 불균형 데이터 세트로 딥러닝 모델의 성능에 큰 영향을 미치는 것을 확인하였다. 3개 내시경 센터에서 진단된 췌장암 환자로부터 다양한 초음파 시스템을 이용하여 EUS 영상을 수집하고 혈관 침범을 진단하기 위해 특성 및 이미지 변환 모델을 활용하여 소스 및 대상 도메인을 효과적으로 변환했다. 제안된 multicenter translation (MCTL) 접근 방식은 세 가지 서로 다른 불균형 데이터 세트에 대해 우수한 분류 성능을 보여주었다. 본 연구에서는 딥러닝 접근 방식을 활용하여 다중 센터의 EUS 이미지에서 췌장암의 혈관 침범 진단을 기능을 향상시키고 데이터 불균형 문제를 해결했다. 두 번째로 자기공명 췌담관조영술(MRCP) 영상과 임상 지표를 이용한 다중 모드 딥러닝 기반 간외 총담관 폐쇄 진단에 대한 연구이다. 자기공명 췌담관조영술은 간외 총담관 폐쇄(EHBDO) 진단에 사용되는 비침습적 기술이다. 본 연구에서는 MRCP 영상과 임상 지표의 다중 모드 데이터를 활용하여 EHBDO 진단을 자동으로 지원하는 분류 파이프라인을 고안하는 것을 목표로 했다. 총담관(CBD) 폐쇄 및 악성종양을 진단하기 위해 MRCP 이미지와 임상 매개변수의 특징을 결합한 딥러닝 접근 방식이 제안되었다. 단일 모드 데이터(임상 매개변수 또는 MRCP 이미지)를 사용한 머신러닝 및 딥러닝 접근 방식과 진단 기능을 비교했을 때 제안된 다중 모드 데이터를 활용한 딥러닝 모델은 우수한 성능을 보였다.</summary>
    <dc:date>2024-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Force Sensing Approach for Autonomous Ultrasound Imaging</title>
    <link rel="alternate" href="https://dspace.ewha.ac.kr/handle/2015.oak/276623" />
    <author>
      <name>Liu, Qian</name>
    </author>
    <id>https://dspace.ewha.ac.kr/handle/2015.oak/276623</id>
    <updated>2026-11-24T16:31:20Z</updated>
    <published>2024-01-01T00:00:00Z</published>
    <summary type="text">Title: Force Sensing Approach for Autonomous Ultrasound Imaging
Ewha Authors: Liu, Qian
Abstract: 로봇을 이용한 자동 초음파 검사에서는 초음파 프로브에 대한 압력과 각도를 일관되게 유지하는 것이 정확한 진단을 위한 고품질 이미지를 얻는 데 중요하다. 일반적으로 접촉시의 압력을 모니터링하는 데 압력 센서와 토크 센서가 사용되지만 센서 배치 상태나 센서 자체의 오작동으로 인한 오류가 많다. 본 연구에서는 이러한 문제를 해결하기 위해 센서를 사용하지 않고 초음파 프로브 양 측간 접촉 압력의 차이를 측정하는 방법을 제안하였다. 제안한 방법은 순차적 초음파 이미지와 CNN-LSTM 네트워크를 이용하여 압력의 차이를 추정하는 딥러닝 기반 접근 방식이다. 제안한 딥러닝 기반 방식을 훈련하고 평가하기 위해 로봇팔, 초음파 영상 시스템, 압력 센서, 그리고 세 가지 생체 조직 모방 팬텀을 사용하여 실험을 수행했다. 제안한 네트워크를 훈련한 후에 팬텀에 적용된 힘의 차이를 -6N에서 6N까지 변경하면서 접촉 압력의 예측 오류를 계산한 결과 평균 제곱 오차 0.251N²를 보였다. 또한, 제안한 접근 방식의 압력 예측 성능을 다양한 CNN-LSTM 기반 방법들과 비교하여 제안 방식이 정확도 측면에서 가장 우수하다는 것을 검증했다. 본 연구에서 제안한 방법은 물리적 센서에 의존하지 않으면서 초음파 프로브의 접촉 압력 추정에 효과적이며 자동 초음파 검사 중에 프로브를 제어하는 데 적용이 가능함을 보였다. 따라서 기존 센서 기반 방법에서의 한계를 해결하면서도 보다 정확하고 안정적으로 로봇을 이용한 초음파 영상화에 적용할 수 있는 방식을 제안하였다. ;During robotic ultrasound examinations, maintaining consistent pressure and angle control over the ultrasound probe is crucial to obtain high-quality images for accurate diagnosis. While force and torque sensors are commonly used to monitor contact force, they are susceptible to inaccuracies due to sensor placement or malfunction. To address these issues, we propose a sensorless approach to estimate the contact force difference between the two sides of the ultrasound probe. Our proposed method utilizes a deep learning-based approach, specifically a CNN-LSTM network, which leverages sequential ultrasound images to estimate force differentials. We conducted experiments using three tissue-mimicking phantoms to train and evaluate our approach. By varying the applied force difference from -6N to 6N on the phantoms, we achieved a mean squared error of 0.251N² in predicting the contact force difference. For performance assessment, we compared our approach with various CNN-LSTM-based methods, demonstrating that our proposed approach outperforms others in terms of accuracy. The results indicate that our proposed method is effective for contact force estimation without relying on physical sensors and can be deployed to control probes during robotic ultrasound examinations. Therefore, our sensorless approach offers a promising solution to address the limitations associated with traditional sensor-based methods, paving the way for more accurate and reliable robotic ultrasound scanning.</summary>
    <dc:date>2024-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Piezoelectric 1D MEMS Scanning Micromirror Fabricated with Bulk PZT Laminated on Stainless Steel Plate</title>
    <link rel="alternate" href="https://dspace.ewha.ac.kr/handle/2015.oak/276619" />
    <author>
      <name>윤현</name>
    </author>
    <id>https://dspace.ewha.ac.kr/handle/2015.oak/276619</id>
    <updated>2026-11-24T16:31:19Z</updated>
    <published>2023-01-01T00:00:00Z</published>
    <summary type="text">Title: Piezoelectric 1D MEMS Scanning Micromirror Fabricated with Bulk PZT Laminated on Stainless Steel Plate
Ewha Authors: 윤현
Abstract: In this research, a metal scanning micromirror with a very simple manufacturing process and structure is developed. In contrast to conventional scanning micromirrors fabricated with single-crystal silicon, stainless steel plate is used as the structural layer material. The piezoelectric driving method is adopted, which is most suitable for driving a separately manufactured metal substrate device. Two types of devices with different cantilever and connector geometry are designed and tested. Fabricated devices are driven by the strain generated in the bulk PZT (lead zirconate titanate) plates attached to the cantilevers formed on both sides of the reflective surface. The structural layer is composed of two cantilevers, two connectors formed on both sides of the cantilevers, a mirror holder, and torsion springs for the mirror is fabricated with 0.1 mm-thick stainless steel (SUS 304) plate. A 5 mm-diameter gold-coated silicon mirror plate was used as the reflective surface. Three different types of bulk PZT plates (PZT-5H, PZT-8, and PZT-5) with two different sizes were tested. A maximum optical scan angle of 26° for model 1 and 44° for model 2 was achieved with PZT-5H at 200 Vpp sinusoidal input voltage. The average resonant frequency of the samples with PZT-5H was 1,264 Hz and 995 Hz for models 1 and 2, respectively. Compared to the device with PZT-5H, the maximum optical scan angle of the devices with PZT-8 and PZT-5 were 71.4 % and 73.5 % for model 1, and 68.6 % and 70.8 % for model 2 at 200 Vpp sinusoidal input. For both models with PZT-5H, the absence of hysteresis was confirmed by measuring the frequency response of mirror deflection during the forward and backward frequency sweeps. A negligible amount of heat was generated at the PZT plate during actuation, confirmed by temperature measurement using a thermal imaging camera. In addition, as a result of a long-term reliability test through 24 hour operation, there was no significant change in the resonant frequency and the scan angle, and no tilt was detected at the initial position of the reflective surface. This study demonstrated the feasibility of utilizing stainless steel plate as the structural layer of a piezoelectric scanning micromirror, which can be used in a 3D (three-dimensional) LiDAR (Light Detection And Ranging) system by combining it with an additional slow vertical scanner.;최근 자율주행자동차 기술이 발전하며, LiDAR (light detection and ranging) 센서의 핵심 요소인 스캐너에 대한 연구가 활발히 진행되고 있다. 그중 MEMS (microelectromechanical systems) 기술을 이용한 스캐너는 마이크로 액추에이터를 이용해 초소형 반사면을 회전시켜 빛의 진행 방향을 조절할 수 있는 소자이다. 이는 모터 기반의 기존 스캐너와 비교할 때 크기, 속도, 비용 면에서 이점을 갖고 있다. &#xD;
본 연구에서는 일반적으로 단결정 실리콘으로 제작되어 온 기존의 스캐닝 미러 대비 제작 공정과 구조가 매우 단순한 금속 재질의 스캐닝 미러를 제안하였고, 별도로 제작된 금속 기판 소자의 구동에 가장 적합한 압전 구동 방식을 채택하였다. 개발된 소자는 반사면 양단에 대칭적으로 부착된 압전 물질인 bulk PZT (lead zirconate titanate) plate에 전압을 인가할 때 발생하는 strain에 의하여 구동된다. 유한요소해석 프로그램을 통해 공진 주파수를 예측하고, 시뮬레이션을 이용해 캔틸레버, 커넥터, 스프링의 길이와 너비 조정을 통해 디자인 최적화를 진행하였다. 제작된 1D 스캐닝 마이크로 미러는 1.0 ~ 1.2 kHz, 200Vpp에서 광학 스캔 각도 26 ~ 44도의 성능을 보였으며 추가 스캐너와 결합하여 2D 스캔 패턴을 생성할 수 있어 3D LiDAR 시스템에 활용될 수 있다.</summary>
    <dc:date>2023-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>End-to-End Lightweight LiDAR-based 3D Human Pose Estimation via 2D Depth Images</title>
    <link rel="alternate" href="https://dspace.ewha.ac.kr/handle/2015.oak/276235" />
    <author>
      <name>김규연</name>
    </author>
    <id>https://dspace.ewha.ac.kr/handle/2015.oak/276235</id>
    <updated>2026-11-24T16:31:45Z</updated>
    <published>2026-01-01T00:00:00Z</published>
    <summary type="text">Title: End-to-End Lightweight LiDAR-based 3D Human Pose Estimation via 2D Depth Images
Ewha Authors: 김규연
Abstract: As intelligent systems such as autonomous vehicles, delivery robots, and indoor monitoring systems are increasingly deployed in human-centered environments, lightweight and accurate human perception has become essential. In this context, 3D human pose estimation provides important cues for understanding human states and actions. light detection and ranging （LiDAR） sensors have attracted attention because they provide direct 3D depth measurements, robust sensing performance, and privacy-preserving perception. However, existing LiDAR-based 3D human pose estimation methods mainly process point clouds directly, resulting in high computational and memory costs. Moreover, many previous approaches rely on cropped human point clouds, limiting their applicability to end-to-end pose estimation from raw LiDAR scenes. In this thesis, we propose a lightweight end-to-end LiDAR-based 3D human pose estimation method specifically designed for deployment in human-centered environments. Unlike conventional 3D direct processing methods, our approach strategically reduces computational complexity by projecting point clouds into 2D depth images and leveraging a lightweight MoveNet, followed by efficient 3D lifting. Furthermore, we introduce a self-occlusion correction algorithm to improve robustness under side-view and bending poses, where depth-based projections often suffer from distortion. Experimental results on benchmark dataset demonstrate that the proposed method achieves competitive pose estimation accuracy while substantially improving efficiency, highlighting its practicality and scalability for real-time LiDAR-based 3D human pose estimation in resource-constrained environments.;자율주행차, 배달 로봇, 실내 모니터링 시스템과 같은 지능형 시스템이 인간 중심 환경에서 점차 활용됨에 따라, 사람을 정확하고 경량적으로 인식하는 기술의 중요성이 커지고 있다. 이러한 맥락에서 3차원 인체 자세 추정 기술은 사람의 상태와 행동을 이해하는 중요한 단서를 제공한다. LiDAR（light detection and ranging） 센서는 직접적인 3차원 거리 정보, 안정적인 센싱 성능, 개인정보 보호 측면의 장점으로 인해 주목받고 있다. 그러나 기존 LiDAR 기반 3차원 인체 자세 추정 방법들은 주로 point cloud를 직접 처리하기 때문에 높은 계산 비용과 메모리 사용량이 요구된다. 또한 많은 기존 연구들은 이미 분리된 사람 point cloud를 입력으로 사용하므로, 실제 raw LiDAR scene으로부터 최종 3차원 자세를 추정하는 end-to-end 구조로 적용하는 데 한계가 있다.&#xD;
본 논문에서는 인간 중심 환경에서의 적용을 목표로 하는 경량 end-to-end LiDAR 기반 3차원 인체 자세 추정 방법을 제안한다. 제안 방법은 기존의 3차원 point cloud 직접 처리 방식과 달리, point cloud를 2D depth image로 투영하고 경량 MoveNet을 활용한 뒤 효율적인 3D lifting을 수행함으로써 계산 복잡도를 줄인다. 또한 depth 기반 projection 과정에서 왜곡이 발생하기 쉬운 side-view 및 bending pose에서의 강건성을 향상시키기 위해 self-occlusion 보정 알고리즘을 도입한다.&#xD;
Benchmark dataset을 이용한 실험 결과, 제안 방법은 경쟁력 있는 자세 추정 정확도를 달성하면서도 효율성을 크게 향상시켰다. 이러한 결과는 제안 방법이 제한된 연산 자원을 갖는 환경에서도 실시간 LiDAR 기반 3차원 인체 자세 추정에 실용적으로 적용 가능함을 보여준다.</summary>
    <dc:date>2026-01-01T00:00:00Z</dc:date>
  </entry>
</feed>

