View : 98 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author조수범-
dc.contributor.author김명수-
dc.contributor.author오창훈-
dc.contributor.author이효정-
dc.date.accessioned2024-05-17T16:31:24Z-
dc.date.available2024-05-17T16:31:24Z-
dc.date.issued2024-
dc.identifier.issn0025-7974-
dc.identifier.otherOAK-35006-
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/268341-
dc.description.abstractTo evaluate the technical feasibility of the alternative snare technique using a 0.018-inch guide wire and 5-French (Fr) catheter for double-J ureteral stent (DJUS) removal. In this retrospective study, 11 DJUS were removed in 9 consecutive patients between July 2023 and October 2023. We evaluated patient characteristics, DJUS characteristics, and procedure characteristics. Out of 11 cases, 8 (72.7%) were successful in removing the DJUS using the alternative snare technique without major complications. The average time between DJUS insertion and removal was 47.4 ± 50.0 days. The most common DJUS size was an 8-Fr, with proximal tips predominantly in the proximal ureter and renal pelvis. The mean procedure time for successful cases was 15.2 ± 16.8 minutes. Three failed cases, attributed to obstructions like debris, were later successfully addressed using the ALN inferior vena cava filter removal kit, forceps, and modified snare technique. The alternative snare technique using a 0.018-inch guidewire and Fr catheter is safe and effective in cases of DJUS removal. © 2024 Lippincott Williams and Wilkins. All rights reserved.-
dc.languageEnglish-
dc.publisherLippincott Williams and Wilkins-
dc.subjectpercutaneous removal-
dc.subjectsnare technique-
dc.subjectureteral stent-
dc.titleTechnical feasibility and safety of the alternative snare technique using a 0.018-inch guide wire and 5-French catheter for double-J ureteral stent removal-
dc.typeArticle-
dc.relation.issue11-
dc.relation.volume103-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.startpageE37525-
dc.relation.journaltitleMedicine (United States)-
dc.identifier.doi10.1097/MD.0000000000037525-
dc.identifier.wosidWOS:001186143600048-
dc.identifier.scopusid2-s2.0-85187991721-
dc.author.googleLim-
dc.author.googleYe Won-
dc.author.googleOh-
dc.author.googleChang Hoon-
dc.author.googleLee-
dc.author.googleHyo Jeong-
dc.author.googleCho-
dc.author.googleSoo Buem-
dc.author.googleKim-
dc.author.googleMyung Soo-
dc.contributor.scopusid조수범(57116811200)-
dc.contributor.scopusid김명수(57199747517)-
dc.contributor.scopusid오창훈(58526043800)-
dc.contributor.scopusid이효정(57209160649)-
dc.date.modifydate20240517134048-
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE