View : 242 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author한경은*
dc.contributor.author조수창*
dc.contributor.author김현진*
dc.date.accessioned2024-02-15T05:12:17Z-
dc.date.available2024-02-15T05:12:17Z-
dc.date.issued2023*
dc.identifier.issn1011-8942*
dc.identifier.otherOAK-34721*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/267900-
dc.description.abstractPurpose: To evaluate repeatability and agreement of chord mu between Scheimpflug tomography (Pentacam HR) and sweptsource optical coherence tomography-based optical biometer (IOLMaster 700). Methods: In this retrospective study, 63 eyes from 33 patients were included. Chord mu, X and Y Cartesian distances between the corneal vertex and the pupil center (Px and Py), and the pupil diameter were compared using two instruments. Repeatability was evaluated using intraclass correlation coefficient (ICC), coefficient of variation (CoV), and within-subject standard deviation (Sw). Interdevice agreement was evaluated using paired t-tests and Bland-Altman plots. Results: Although Sw values for all parameters were similar between the two devices, CoV values of chord mu and pupil diameter were lower, and ICC values of those parameters were higher, in the IOLMaster 700 than in the Pentacam HR. Chord mu and pupil diameter values were higher in IOLMaster 700 than Pentacam HR (p < 0.01). The width of the 95% limit of agreement was wide for all parameters. Conclusions: IOLMaster 700 showed better repeatability than Pentacam HR in chord mu, Px, Py, and pupil diameter values. Because there were statistically significant differences and a low level of agreement in chord mu and pupil diameter values between the two devices, they cannot be used interchangeably. © 2023 The Korean Ophthalmological Society.*
dc.languageEnglish*
dc.publisherKorean Ophthalmological Society (KOS)*
dc.subjectAngle kappa*
dc.subjectChord mu*
dc.subjectPupil diameter*
dc.subjectScheimpflug tomography*
dc.subjectSwept-source optical coherence tomography*
dc.titleRepeatability and Agreement of Chord Mu between Scheimpflug Tomography and Swept-Source Optical Coherence Tomography*
dc.typeArticle*
dc.relation.issue6*
dc.relation.volume37*
dc.relation.indexSCOPUS*
dc.relation.indexKCI*
dc.relation.startpage510*
dc.relation.lastpage517*
dc.relation.journaltitleKorean Journal of Ophthalmology*
dc.identifier.doi10.3341/kjo.2023.0092*
dc.identifier.scopusid2-s2.0-85179479935*
dc.author.googleKim*
dc.author.googleNa Hyun*
dc.author.googleHyun Jin*
dc.author.googleCho*
dc.author.googleSoo Chang*
dc.author.googleHan*
dc.author.googleKyung Eun*
dc.contributor.scopusid한경은(37031161100)*
dc.contributor.scopusid조수창(57199759973)*
dc.contributor.scopusid김현진(55790161000;57205142350;57222375718;57218261214)*
dc.date.modifydate20240527142916*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE