View : 173 Download: 0

Comparison of intraocular lens power calculation formulas in patients with a history of acute primary angle-closure attack

Title
Comparison of intraocular lens power calculation formulas in patients with a history of acute primary angle-closure attack
Authors
KimNa HyunGimYujinChoiKyu-RyongSuhWoolJunRoo MinHanKyung Eun
Ewha Authors
최규룡전루민한경은서울
SCOPUS Author ID
최규룡scopus; 전루민scopus; 한경은scopus; 서울scopus
Issue Date
2023
Journal Title
BMC Ophthalmology
ISSN
1471-2415JCR Link
Citation
BMC Ophthalmology vol. 23, no. 1
Keywords
Acute primary angle closureAxial lengthIntraocular lens calculation formulaLaser peripheral iridotomyPrediction
Publisher
BioMed Central Ltd
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Background: To compare the accuracy of nine intraocular lens (IOL) power calculation formulas, including three traditional formulas (SRK/T, Haigis, and Hoffer Q) and six new-generation formulas (Barrett Universal II [BUII], Hill-Radial Basis Function [RBF] 3.0, Kane, Emmetropia verifying optical [EVO], Ladas Super, and Pearl-DGS) in patients who underwent cataract surgery after acute primary angle closure (APAC). Methods: In this retrospective cross-sectional study, 44 eyes of 44 patients (APAC) and 60 eyes of 60 patients (control) were included. We compared the mean absolute error, median absolute error (MedAE), and prediction error after surgery. Subgroup analyses were performed on whether axial length (AL) or preoperative laser peripheral iridotomy affected the postoperative refractive outcomes. Results: In the APAC group, all formulas showed higher MedAE and more myopic shift than the control group (all P < 0.05). In APAC eyes with AL ≥ 22 mm, there were no differences in MedAEs according to the IOL formulas; however, in APAC eyes with AL < 22 mm, Haigis (0.49 D) showed lower MedAE than SRK/T (0.82 D) (P = 0.036) and Hill-RBF 3.0 (0.54 D) showed lower MedAE than SRK/T (0.82 D), Hoffer Q (0.75 D) or Kane (0.83 D) (P = 0.045, 0.036 and 0.027, respectively). Pearl-DGS (0.63 D) showed lower MedAE than Hoffer Q (0.75 D) and Kane (0.83 D) (P = 0.045 and 0.036, respectively). Haigis and Hill-RBF 3.0 showed the highest percentage (46.7%) of eyes with PE within ± 0.5 D in APAC eyes with AL < 22 mm. Iridectomized eyes did not show superior precision than the non-iridotomized eyes in the APAC group. Conclusions: Refractive errors in the APAC group were more myopic than those in the control group. Haigis and Hill-RBF 3.0 showed high precision in the eyes with AL < 22 mm in the APAC group. © 2023, The Author(s).
DOI
10.1186/s12886-023-03232-5
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE