View : 290 Download: 0

Long-Term (up to 38 Years) Failure Modes of Total Hip Arthroplasty in Adult Patients Who Had Childhood Infection of Hip

Title
Long-Term (up to 38 Years) Failure Modes of Total Hip Arthroplasty in Adult Patients Who Had Childhood Infection of Hip
Authors
Kim, Young-HooPark, Jang-WonJang, Young-SooKim, Eun-Jung
Ewha Authors
박장원
SCOPUS Author ID
박장원scopus
Issue Date
2022
Journal Title
JOURNAL OF ARTHROPLASTY
ISSN
0883-5403JCR Link

1532-8406JCR Link
Citation
JOURNAL OF ARTHROPLASTY vol. 37, no. 8, pp. 1612 - 1617
Keywords
long-termfailure modestotal hip arthroplastychildhood infectionpast design of prosthesispoor quality of polyethylene
Publisher
CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Background: The long-term failure modes of total hip arthroplasty (THA) in adult patients who had childhood infection have not been documented. The purpose of this study is to analyze the longer term clinical and radiographic results, prevalence of osteolysis, and survival rate of THA. Methods: We reviewed the results of 142 patients (145 hips) (mean age 41.9 years). The age of the pa-tients at the time that the infection was contracted was an average of 7.1 years (range 1-11). The average interval between active infection and THA was 34.5 years. All but 2 hips (1 patient) had a quiescent period of infection of more than 10 years. The average duration of follow-up after THA was 31.5 years (range 25-38). Results: All but 2 hips with more than 10 years of quiescent infection had no recurrence of infection. The remaining 2 hips in the 1 patient with only 7 years of quiescent infection had a recurrence of infection. Seventy-eight of 145 hips (54%) underwent isolated cup revision for loosening, or osteolysis, or dislo-cation. Thirty (21%) femoral components were revised for aseptic loosening and/or osteolysis. The Kaplan-Meier survivorship curve at 31.5 years showed that the survival rate of the acetabular component was 46% (95% confidence interval 39-74) and that of the femoral component was 79% (95% confidence interval 73-89). Conclusion: Contributing factors to the high failure rate of THAs were less than optimal prostheses and poor quality of polyethylene during the time period of this study. (c) 2022 Elsevier Inc. All rights reserved.
DOI
10.1016/j.arth.2022.03.064
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE