View : 390 Download: 0

Accuracy of automated identification of lateral cephalometric landmarks using cascade convolutional neural networks on lateral cephalograms from nationwide multi-centres

Title
Accuracy of automated identification of lateral cephalometric landmarks using cascade convolutional neural networks on lateral cephalograms from nationwide multi-centres
Authors
Kim J.Kim I.Kim Y.-J.Kim M.Cho J.-H.Hong M.Kang K.-H.Lim S.-H.Kim S.-J.Kim Y.H.Kim N.Sung S.-J.Baek S.-H.
Ewha Authors
김민지
SCOPUS Author ID
김민지scopus
Issue Date
2021
Journal Title
Orthodontics and Craniofacial Research
ISSN
1601-6335JCR Link
Citation
Orthodontics and Craniofacial Research vol. 24, no. S2, pp. 59 - 67
Publisher
John Wiley and Sons Inc
Indexed
SCIE; SCOPUS scopus
Document Type
Article
Abstract
Objective: To investigate the accuracy of automated identification of cephalometric landmarks using the cascade convolutional neural networks (CNN) on lateral cephalograms acquired from nationwide multi-centres. Settings and sample population: A total of 3150 lateral cephalograms were acquired from 10 university hospitals in South Korea for training. Materials and Methods: We evaluated the accuracy of the developed model with independent 100 lateral cephalograms as an external validation. Two orthodontists independently identified the anatomic landmarks of the test data set using the V-ceph software (version 8.0, Osstem, Seoul, Korea). The mean positions of the landmarks identified by two orthodontists were regarded as the gold standard. The performance of the CNN model was evaluated by calculating the mean absolute distance between the gold standard and the automatically detected positions. Factors associated with the detection accuracy for landmarks were analysed using the linear regression models. Results: The mean inter-examiner difference was 1.31 ± 1.13 mm. The overall automated detection error was 1.36 ± 0.98 mm. The mean detection error for each landmark ranged between 0.46 ± 0.37 mm (maxillary incisor crown tip) and 2.09 ± 1.91 mm (distal root tip of the mandibular first molar). A significant difference in the detection accuracy among cephalograms was noted according to hospital (P =.011), sensor type (P <.01), and cephalography machine model (P <.01). Conclusion: The automated cephalometric landmark detection model may aid in preliminary screening for patient diagnosis and mid-treatment assessment, independent of the type of the radiography machines tested. © 2021 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd
DOI
10.1111/ocr.12493
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE