View : 359 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author한종인*
dc.contributor.author김동연*
dc.contributor.author정경아*
dc.contributor.author이종화*
dc.date.accessioned2022-02-22T16:31:05Z-
dc.date.available2022-02-22T16:31:05Z-
dc.date.issued2021*
dc.identifier.issn1011-8934*
dc.identifier.issn1598-6357*
dc.identifier.otherOAK-30768*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/260608-
dc.description.abstractBackground: During robotic gynecologic pneumoperitoneum surgery in the Trendelenburg position, aeration loss leads to perioperative atelectasis. Recently developed ventilator mode pressure-controlled ventilation volume-guaranteed (PCV-VG) mode could provide adequate ventilation with lower inspiratory pressure compared to volume-controlled ventilation (VCV); we hypothesized that PCV-VG mode may be beneficial in reducing perioperative atelectasis via low tidal volume (VT) of 6 mL/kg ventilation during robotic gynecologic pneumoperitoneum surgery in the Trendelenburg position. We applied lung ultrasound score (LUS) for detecting perioperative atelectasis. We aimed to compare perioperative atelectasis between VCV and PCV-VG with a low VT of 6 mL/kg during pneumoperitoneum surgery in the Trendelenburg position using LUS. Methods: Patients scheduled for robotic gynecologic surgery were randomly allocated to the VCV (n = 41) or PCV-VG group (n = 41). LUS, ventilatory, and hemodynamic parameters were evaluated at T1 (before induction), T2 (10 minutes after induction in the supine position), T3 (10 minutes after desufflation of CO2 in the supine position), and T4 (30 minutes after emergence from anesthesia in the recovery room). Results: Eighty patients (40 with PCV-VG and 40 with VCV) were included. Demographic data showed no significant differences between the groups. The total LUS has changed from baseline to T4, 0.63 (95% confidence interval [CI], 0.32, 0.94) to 1.77 (95% CI, 1.42, 2.21) in the VCV group and 0.86 (95% CI, 0.56, 1.16) to 1.43 (95% CI, 1.08, 1.78) in the PCV-VG group (P = 0.170). In both groups, total LUS increased significantly compared to the baseline values. Conclusion: Using a low VT of 6 mL/kg during pneumoperitoneum surgery in the Trendelenburg position, our study showed no evidence that PCV-VG ventilation was superior to VCV in terms of perioperative atelectasis.*
dc.languageEnglish*
dc.publisherKOREAN ACAD MEDICAL SCIENCES*
dc.subjectLung Ultrasonography*
dc.subjectAtelectasis*
dc.subjectGynecologic Anesthesia*
dc.subjectMechanical Ventilation*
dc.titleAssessment of Perioperative Atelectasis Using Lung Ultrasonography in Patients Undergoing Pneumoperitoneum Surgery in the Trendelenburg Position: Aspects of Differences according to Ventilatory Mode*
dc.typeArticle*
dc.relation.issue50*
dc.relation.volume36*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.indexKCI*
dc.relation.journaltitleJOURNAL OF KOREAN MEDICAL SCIENCE*
dc.identifier.doi10.3346/jkms.2021.36.e334*
dc.identifier.wosidWOS:000737271000002*
dc.identifier.scopusid2-s2.0-85121820784*
dc.author.googleLee, Youn Young*
dc.author.googleHan, Jong In*
dc.author.googleKang, Bo Kyung*
dc.author.googleJeong, Kyungah*
dc.author.googleLee, Jong Wha*
dc.author.googleKim, Dong Yeon*
dc.contributor.scopusid한종인(57206610922)*
dc.contributor.scopusid김동연(55511080500)*
dc.contributor.scopusid정경아(13309069700)*
dc.contributor.scopusid이종화(27171076400;57356274600)*
dc.date.modifydate20240415132314*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE