View : 465 Download: 0

Early restoration of shoulder function in patients with the Grammont prosthesis compared to lateralized humeral design in reverse shoulder arthroplasty

Title
Early restoration of shoulder function in patients with the Grammont prosthesis compared to lateralized humeral design in reverse shoulder arthroplasty
Authors
Lee, Jae-HooChun, Yong-MinKim, Doo-SupLee, Doo-HyungShin, Sang-Jin
Ewha Authors
신상진
SCOPUS Author ID
신상진scopus
Issue Date
2021
Journal Title
JOURNAL OF SHOULDER AND ELBOW SURGERY
ISSN
1058-2746JCR Link

1532-6500JCR Link
Citation
JOURNAL OF SHOULDER AND ELBOW SURGERY vol. 30, no. 11, pp. 2533 - 2542
Keywords
Reverse shoulder arthroplastyrotator cuff tearcuff tear arthroplastyGrammont prosthesislateralized humeral designscapular notching
Publisher
MOSBY-ELSEVIER
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Background: This study aimed to compare the clinical outcomes and radiographic parameters of patients after reverse shoulder arthroplasty (RSA) between the Grammont prosthesis and lateralized humeral design prosthesis. Methods: A total of 114 patients who underwent RSA with a lateralized humeral design (group L; 71 shoulders) and medialized humeral design (group M; 43 shoulders) prosthesis for cuff tear arthropathy or irreparable rotator cuff tear were enrolled. Clinical outcomes including visual analog scale (VAS), American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and Constant scores and range of motion (ROM) were serially followed up at postoperative 3, 6, 12, and 24 months. Radiographic parameters were measured to evaluate preoperative and postoperative status. Results: Both prostheses demonstrated similar clinical outcomes and shoulder function preoperatively and at postoperative 2 years (P >.05). However, patients in group M had significantly better postoperative active forward flexion (postoperative 3 months, 115 degrees +/- 12 degrees vs. 101 degrees +/- 14 degrees; P <.001; 6 months, 125 degrees +/- 13 degrees vs. 118 degrees +/- 13 degrees; P <.013) and abduction (3 months, 105 degrees +/- 12 degrees vs. 98 degrees +/- 12 degrees; P = .002); VAS (3 months, 3.1 +/- 1.2 vs. 3.7 +/- 1.4; P = .031; 6 months, 2.3 +/- 1.1 vs. 2.8 +/- 1.3; P = .038); ASES (3 months, 64.2 +/- 7.0 vs. 60.4 +/- 9.2; P = .022; 6 months, 70.6 +/- 6.0 vs. 66.6 +/- 8.1; P = .007); and Constant scores (6 months, 59.6 +/- 6.9 vs. 55.7 +/- 9.3; P = .020). Group L showed a significantly lower rate of scapular notching than group M (15.5% vs. 41.8%; P < .001). The position of the proximal humerus in group L was more lateralized and less distalized than in group M after RSA. Conclusions: RSA with both the Grammont and lateralized humeral design prostheses provided similar shoulder ROM restoration and functional improvements at a minimum of 2 years. However, patients with a humeral lateralized prosthesis showed slower recovery of shoulder function and ROM up to postoperative 6 months despite a lower incidence of scapular notching. (C) 2021 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
DOI
10.1016/j.jse.2021.03.145
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE