View : 523 Download: 86

Effects of Intraoperative Ventilation Strategy on Perioperative Atelectasis Assessed by Lung Ultrasonography in Patients Undergoing Open Abdominal Surgery: a Prospective Randomized Controlled Study

Title
Effects of Intraoperative Ventilation Strategy on Perioperative Atelectasis Assessed by Lung Ultrasonography in Patients Undergoing Open Abdominal Surgery: a Prospective Randomized Controlled Study
Authors
Cho, SooyoungOh, Hye-WonChoi, Min HeeLee, Hyun JungWoo, Jae Hee
Ewha Authors
우재희조수영오혜원
SCOPUS Author ID
우재희scopus; 조수영scopus; 오혜원scopus
Issue Date
2020
Journal Title
JOURNAL OF KOREAN MEDICAL SCIENCE
ISSN
1011-8934JCR Link

1598-6357JCR Link
Citation
JOURNAL OF KOREAN MEDICAL SCIENCE vol. 35, no. 39
Keywords
Mechanical VentilationAbdominal SurgeryLung UltrasonographyTidal VolumeAtelectasis
Publisher
KOREAN ACAD MEDICAL SCIENCES
Indexed
SCIE; SCOPUS; KCI WOS
Document Type
Article
Abstract
Background: Protective mechanical ventilation using low tidal volume has been introduced to surgical patients to reduce the incidence of postoperative pulmonary complications. We investigated the effects of protective ventilation (PV) techniques on anesthesia-induced atelectasis identified via lung ultrasonography in patients undergoing abdominal surgery. Methods: A total of 42 adult patients who were scheduled for open abdominal surgery with an expected duration > 2 hours were included in the study. Patients were randomized to receive either conventional ventilation (CV; tidal volume of 9-10 mL/kg predicted body weight [PBW] with no positive end-expiratory pressure [PEEP]) or PV (tidal volume of 6-8 mL/kg PBW and 5 cmH(2)O PEEP) via pressure-controlled ventilation with volume guaranteed. Lung ultrasonography was performed at four predefined time points to assess perioperative atelectasis by dividing each hemithorax into six quadrants based on a modified lung ultrasound (LUS) scoring system. Results: The tidal volume delivered to patients was 9.65 +/- 1.65 mL/kg PBW in the CV group and 6.31 +/- 0.62 mL/kg PBW in the PV group. Ventilation using low tidal volume led to similar LUS scores in all lung areas and at all time points compared to ventilation using high tidal volume. There was no significant difference between the groups in the number of patients requiring recruitment maneuvers at the end of surgery. Conclusion: Ventilation with low tidal volume combined with 5 cmH(2)O PEEP did not cause further loss of aeration compared to ventilation with high tidal volume. Low tidal volume ventilation can be used in patients without lung injury based on lung assessment by bedside lung ultrasonography.
DOI
10.3346/jkms.2020.35.e327
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
0063JKMS_jkms-35-e327.pdf(3.13 MB) Download
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE