View : 469 Download: 0

Comparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis

Title
Comparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis
Authors
Song, ShinjeongHeo, RanLee, Sang-EunPark, JinkiLee, JinyongKim, SujinCho, In JeongChang, Hyuk-Jae
Ewha Authors
조인정
SCOPUS Author ID
조인정scopus
Issue Date
2019
Journal Title
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES
ISSN
0742-2822JCR Link

1540-8175JCR Link
Citation
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES vol. 36, no. 12, pp. 2241 - 2250
Keywords
atherosclerosiscarotid arteryplaque volumethree-dimensional echocardiography
Publisher
WILEY
Indexed
SCIE; SCOPUS WOS
Document Type
Article
Abstract
Aims Two-dimensional ultrasound (2D-US) is the mainstay imaging technique used to evaluate carotid atherosclerosis. An automated single sweep three-dimensional ultrasound (3D-US) technique became available. We evaluated the feasibility and accuracy of 3D-US in the assessment of carotid plaques compared to those of 2D-US. Carotid computed tomography angiography (CTA) was used as a reference. Methods and results Among 126 stroke patients who underwent carotid 2D-US, 73 underwent 3D-US and carotid CTA. 3D-US was pursued when there were carotid plaques or when area stenosis was >= 20% by 2D-US. Both 2D- and 3D-US images of the carotid arteries were acquired using a dedicated ultrasound system that was equipped with the single sweep volumetric transducer. In total, 266 arteries from 73 patients were selected for comparison of the detection rate of carotid plaques between 2D- and 3D-US. Among the 73 patients, carotid CTA detected 139 plaques. 3D-US demonstrated a higher detection rate of carotid plaques than did 2D-US (108 plaques (77.9%) vs. 70 plaques (50.4%)) when using carotid CTA as a reference standard. Carotid plaque volume (PV) of 133 vessels from 73 patients were quantitatively evaluated using both 3D-US and carotid CTA. Plaque volume of carotid artery was comparable between 3D-US and CTA (148.5 +/- 133.0 mm(3) vs. 154.1 +/- 134.6 mm(3), P = .998, R: 0.9825, P-value for r < .001). Conclusion 3D-US using a single sweep technique was a feasible and accurate method of detecting arterial plaques and assessing plaque volume.
DOI
10.1111/echo.14543
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE