Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박장원 | * |
dc.date.accessioned | 2020-01-14T16:30:15Z | - |
dc.date.available | 2020-01-14T16:30:15Z | - |
dc.date.issued | 2020 | * |
dc.identifier.issn | 0883-5403 | * |
dc.identifier.issn | 1532-8406 | * |
dc.identifier.other | OAK-26232 | * |
dc.identifier.uri | https://dspace.ewha.ac.kr/handle/2015.oak/252405 | - |
dc.description.abstract | Background: Long-term result of the ultra-short anatomic cementless stem in the patients with idiopathic or ethanol-induced osteonecrosis of the femoral head has not been assessed. The aim of this study is to evaluate the long-term clinical, radiographic, computed tomography scan, and dual-energy X-ray absorptiometry scanning results, and survivorship of this specific femoral stem in patients with idiopathic or ethanol-induced femoral head osteonecrosis. Methods: Two hundred fifty-six patients (335 hips) with an average age of 49.8 years (range 20-63) were enrolled in the current study. All patients underwent dual-energy X-ray absorptiometry scanning of the acetabulum and proximal femur preoperatively and at final follow-up. Computed tomography scan was obtained in all patients at final follow-up. The mean follow-up was 14.7 years (range 13-16). Results: At final follow-up, the average Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 94 points, 12 points, and 8 points, respectively. Four stems (1%) underwent revision for aseptic loosening. One acetabular component (0.3%) was revised for recurrent dislocation. No hip was revised for squeaking or clicking sound. Survivorship of the femoral stem was 99.0% (95% confidence interval 94-100) and that of the acetabular component was 99.4% (95% confidence interval 95-100) at 14.7 years. Conclusion: Ultra-short proximal loading anatomic uncemented femoral stems with ceramic-on-ceramic bearings have excellent survivorship free from aseptic loosening and good clinical results at long term. (C) 2019 Elsevier Inc. All rights reserved. | * |
dc.language | English | * |
dc.publisher | CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS | * |
dc.subject | total hip arthroplasty | * |
dc.subject | ultra-short | * |
dc.subject | anatomic cementless stem | * |
dc.subject | ceramic-on-ceramic bearing | * |
dc.subject | idiopathic or ethanol induced | * |
dc.subject | osteonecrosis | * |
dc.title | Ultra-Short Anatomic Uncemented Femoral Stem and Ceramic-on-Ceramic Bearing in Patients With Idiopathic or Ethanol-Induced Femoral Head Osteonecrosis | * |
dc.type | Article | * |
dc.relation.issue | 1 | * |
dc.relation.volume | 35 | * |
dc.relation.index | SCIE | * |
dc.relation.index | SCOPUS | * |
dc.relation.startpage | 212 | * |
dc.relation.lastpage | 218 | * |
dc.relation.journaltitle | JOURNAL OF ARTHROPLASTY | * |
dc.identifier.doi | 10.1016/j.arth.2019.08.047 | * |
dc.identifier.wosid | WOS:000501844300037 | * |
dc.identifier.scopusid | 2-s2.0-85072247938 | * |
dc.author.google | Kim, Young-Hoo | * |
dc.author.google | Park, Jang-Won | * |
dc.contributor.scopusid | 박장원(55645949000) | * |
dc.date.modifydate | 20240220120149 | * |