View : 522 Download: 0

Intraoperative localization of the parathyroid glands with indocyanine green and Firefly(R) technology during BABA robotic thyroidectomy

Title
Intraoperative localization of the parathyroid glands with indocyanine green and Firefly(R) technology during BABA robotic thyroidectomy
Authors
Yu, Hyeong WonChung, Joon WooYi, Jin WookSong, Ra-YeongLee, Joon-HyopKwon, HyungjuKim, Su-jinChai, Young JunChoi, June YoungLee, Kyu Eun
Ewha Authors
권형주
SCOPUS Author ID
권형주scopus
Issue Date
2017
Journal Title
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES
ISSN
0930-2794JCR Link

1432-2218JCR Link
Citation
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES vol. 31, no. 7, pp. 3020 - 3027
Keywords
Bilateral axillo-breast approachRobotic thyroidectomyParathyroid glandsIndocyanine green fluorescenceNear infraredFirefly technology
Publisher
SPRINGER
Indexed
SCIE; SCOPUS WOS
Document Type
Article
Abstract
Background It is unclear whether near-infrared (NIR) light-induced indocyanine green (ICG) fluorescence can effectively identify, and thus permit the preservation of, parathyroid glands in bilateral axillo-breast approach (BABA) robotic thyroidectomy. This case-control study with a prospectively recruited consecutive series and a retrospectively selected control group assessed the usefulness of ICG with Firefly(R) technology to identify the parathyroid glands intraoperatively during BABA robotic thyroidectomy. Methods All consecutive patients (N = 22) who were scheduled to undergo BABA robotic thyroidectomy for papillary thyroid carcinoma in December 2013-August 2015 and met the study eligibility criteria were recruited prospectively. ICG fluorescence was used with the Firefly system (NIR illuminator: 805 nm; filter: 825 nm) integrated in the da Vinci Si robot system to identify the lower parathyroid glands. Parathyroid hormone levels were recorded on postoperative days 0, 1, 2, and 14. Propensity score matching was used to identify an age-, gender-, tumor size-, and operation type-matched group of control patients who underwent BABA robotic thyroidectomy without the Firefly system. The two groups were compared in terms of parathyroid-related outcomes. Results ICG fluorescence-mediated identification of the parathyroid and thyroid glands required on average (range) 203 +/- 89 (125-331) and 207 +/- 112 (130-356) s, respectively. The mean (range) fluorescence duration in these glands was 20.8 +/- 6.0 (16.6-35.8) and 20.1 +/- 7.3 (15.5-33.8) min, respectively. The ICG group had a significantly lower rate of incidental parathyroidectomy than the control group (0 vs. 15.9%, P = 0.048). Conclusions ICG with NIR light may feasibly and safely identify the parathyroid glands in BABA robotic thyroidectomy.
DOI
10.1007/s00464-016-5330-y
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE