View : 63 Download: 0

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Title
Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study
Authors
You S.K.Choi Y.H.Cheon J.-E.Kim W.S.Kim I.-O.Lee S.M.Cho H.-H.
Ewha Authors
조현혜
Issue Date
2019
Journal Title
Abdominal Radiology
ISSN
2366-004XJCR Link
Citation
Abdominal Radiology vol. 44, no. 5, pp. 1928 - 1935
Keywords
ChildrenComputed tomographyDose reductionIodine concentrationLow tube voltage
Publisher
Springer New York LLC
Indexed
SCIE; SCOPUS scopus
Document Type
Article
Abstract
Purpose: To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. Materials and methods: The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded. Results: The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively). Conclusion: The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality. © 2019, Springer Science+Business Media, LLC, part of Springer Nature.
DOI
10.1007/s00261-019-01896-6
Appears in Collections:
의료원 > 의료원 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE