View : 622 Download: 0

Feasibility of myocardial PET imaging using a benzylguanidine analog: meta-(3-[18F]fluoropropyl)benzylguanidine ([18F]mFPBG)

Title
Feasibility of myocardial PET imaging using a benzylguanidine analog: meta-(3-[18F]fluoropropyl)benzylguanidine ([18F]mFPBG)
Authors
Woo S.-K.Moon B.S.Kim B.S.Kim M.H.Lee Y.J.Jung J.H.Lee K.C.Seo Y.Kim W.Lim S.M.Lee B.C.Kim S.E.
Ewha Authors
김범산
SCOPUS Author ID
김범산scopus
Issue Date
2018
Journal Title
Nuclear Medicine and Biology
ISSN
0969-8051JCR Link
Citation
Nuclear Medicine and Biology vol. 61, pp. 63 - 70
Keywords
18FCardiac sympathetic innervationGuanidineMyocardial infarctionPET
Publisher
Elsevier Inc.
Indexed
SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Introduction: Global and regional sympathetic activity in the heart can be evaluated using [123I]meta-iodobenzylguanidine ([123I]mIBG) imaging. However, [123I]mIBG is associated with low image spatial resolution and sensitivity in cardiac imaging. We investigated the capability of an F-18-labeled mIBG derivative, meta-(3-[18F]fluoropropyl)benzylguanidine ([18F]mFPBG), for identifying ischemic and viable myocardium in a rat model of myocardial infarction. Materials and methods: The ex vivo biodistribution and in vivo metabolic stability of [18F]mFPBG were investigated in Sprague–Dawley rats. Selective cardiac adrenergic activation was confirmed via a blocking experiment involving pretreatment with desipramine (2 mg kg−1), followed by the administration of [18F]mFPBG. Imaging properties of [18F]mFPBG were compared with those of traditional cardiac imaging radiotracers ([123I]mIBG and [99mTc]MIBI) in a rat model of myocardial infarction. Non-invasive image-based measurements of infarct sizes were then compared with histological findings by using Bland–Altman analysis. Results: The differences in infarct sizes determined using histological analysis and [18F]mFPBG PET were −2.55 ± 4.99% (range: −12.33 to 7.22), −2.35 ± 3.32% (range: −8.87 to 4.16), and −3.15 ± 6.16% (range: −15.24 to 8.93) at 5, 20, and 40 min, respectively. Furthermore, [18F]mFPBG PET was superior to traditional imaging methods in assessing the degree of ischemia in areas of myocardial infarction, as well as the actual infarct size. Conclusion: Compared to [123I]mIBG, [18F]mFPBG showed improved spatial resolution and sensitivity in a rat model of myocardial infarction. This result suggested that [18F]mFPBG is a promising cardiac PET imaging agent for potential diagnostic application in PET cardiology. © 2018 Elsevier Inc.
DOI
10.1016/j.nucmedbio.2018.04.005
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE