View : 662 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author홍기숙-
dc.contributor.author정태동-
dc.date.accessioned2018-12-07T16:30:32Z-
dc.date.available2018-12-07T16:30:32Z-
dc.date.issued2017-
dc.identifier.issn2234-3806-
dc.identifier.otherOAK-21016-
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/247343-
dc.description.abstractBackground: We aimed to assess the performance of the five creatinine-based equations commonly used for estimates of the glomerular filtration rate (EGFR), namely, the creatinine-based Chronic Kidney Disease Epidemiology Collaboration (CKD-EPIcr), Asian CKD-EPI, revised Lund-Malmö (revised LM), full age spectrum (FAS), and Korean FAS equations, in the Korean population. Methods: A total of 1, 312 patients, aged 20 yr and above who underwent 51Cr-EDTA GFR measurements (mGFR), were enrolled. The bias (EGFR-mGFR) and precision (root mean square error [RMSE]) were calculated. The accuracy (P30) of four EGFR equations was compared to that of the CKD-EPIcr equation. P30 was defined as the percentage of patients whose EGFR was within±30% of the mGFR. Results: The mean bias (mL·min-1·1.73 m-2) of the five EGFR equation was as follows: CKD-EPIcr, -0.6; Asian CKD-EPI, 2.7; revised LM, -6.5; FAS, -2.5; and Korean FAS, -0.2. The bias of the Asian CKD-EPI, revised LM, and FAS equations showed a significant difference from zero (P<0.001). The RMSE values were as follows: CKD-EPIcr, 15.6; Asian CKD-EPI, 15.6; revised LM, 17.9; FAS, 16.3; and Korean FAS, 15.8. There were no significant differences in the P30 except for the Asian CKD-EPI equation: CKD-EPIcr, 76.6%; Asian CKD-EPI, 74.7%; revised LM, 75.8%; FAS, 76.0%; and Korean FAS, 75.8%. Conclusions: The CKD-EPIcr and Korean FAS equations showed equivalent analytical and clinical performances in the Korean adult population. © 2017 Korean Society for Laboratory Medicine.-
dc.languageEnglish-
dc.publisherSeoul National University, Institute for Cognitive Science-
dc.subjectAccuracy-
dc.subjectComparison-
dc.subjectCreatinine-
dc.subjectEquation-
dc.subjectGlomerular filtration rate-
dc.titleAccuracy assessment of five equations used for estimating the glomerular filtration rate in Korean adults-
dc.typeArticle-
dc.relation.issue5-
dc.relation.volume37-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.indexKCI-
dc.relation.startpage371-
dc.relation.lastpage380-
dc.relation.journaltitleAnnals of Laboratory Medicine-
dc.identifier.doi10.3343/alm.2017.37.5.371-
dc.identifier.wosidWOS:000405445700002-
dc.identifier.scopusid2-s2.0-85021998947-
dc.author.googleJeong T.-D.-
dc.author.googleCho E.-J.-
dc.author.googleLee W.-
dc.author.googleChun S.-
dc.author.googleHong K.-S.-
dc.author.googleMin W.-K.-
dc.contributor.scopusid홍기숙(26324662900)-
dc.contributor.scopusid정태동(56651793600)-
dc.date.modifydate20210708162034-
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE