View : 588 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author편욱범*
dc.date.accessioned2018-12-07T16:30:29Z-
dc.date.available2018-12-07T16:30:29Z-
dc.date.issued2017*
dc.identifier.issn1532-0820*
dc.identifier.otherOAK-21197*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/247330-
dc.description.abstractWhich preclinical models are best suited for restenosis research remains uncertain. Here we compared the restenotic responses after balloon or stent overstretch injury in a porcine coronary artery. A total of 30 coronary lesions in 5 pigs were treated by balloon overdilatation or oversized stent implantation at various balloon-to-artery (B:A) ratios. Four weeks later, the lesions were examined in vivo by using coronary angiography, intravascular ultrasound, and optical coherence tomography (OCT). At follow-up, the lumen area stenosis and plaque burden at the minimal lumen area site were greater in stented sites than in balloon injury site (lumen area stenosis, 21.7 ± 8.9% compared with 32.8 ± 12.1%; plaque burden, 30.1% ± 10.1% compared with 44.7% ± 10.1%, respectively). The remodeling index was significantly smaller for the balloon-injury group than the stent group (0.86 ± 0.11 compared with 1.00 ± 0.04). Only the stent group that was dilated at a high B:A ratio resulted in increased plaque burden. In the balloon-injury sites, high B:A ratios were significantly associated with greater negative remodeling. Tissue morphology assessment by OCT revealed that the predominant pattern in balloon injury sites was homogeneous, whereas that in stented sites was a layered to heterogeneous pattern. Neointimal proliferation was significantly greater after oversized stenting than after balloon overstretch injury. Together these findings suggest that stent overexpansion of porcine coronary arteries might be appropriate for researching restenosis than is the balloon overstretch injury model. Copyright 2017 by the American Association for Laboratory Animal Science.*
dc.description.sponsorshipUniversität Hamburg*
dc.languageEnglish*
dc.publisherAmerican Association for Laboratory Animal Science*
dc.titleDifferences in vascular response between balloon overstretch and stent overexpansion in nonatherosclerotic porcine coronary arteries*
dc.typeArticle*
dc.relation.issue4*
dc.relation.volume67*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage350*
dc.relation.lastpage355*
dc.relation.journaltitleComparative Medicine*
dc.identifier.wosidWOS:000407523400006*
dc.identifier.scopusid2-s2.0-85028470100*
dc.author.googleMitsutake Y.*
dc.author.googleReifart J.*
dc.author.googlePyun W.B.*
dc.author.googleLyons J.K.*
dc.author.googleDeuse T.*
dc.author.googleSchrepfer S.*
dc.author.googleIkeno F.*
dc.contributor.scopusid편욱범(6508352922)*
dc.date.modifydate20240123092816*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE