- The purpose of this study was to assess (1) the prevalence of the fracture of ceramic heads implanted on used trunnions of well-fixed stems without using a titanium adapter sleeve; (2) the prevalence of trunnionosis secondary to fretting and/or corrosion at the trunnion of the well-fixed stem; and (3) clinical and radiographic results and the survival rate of the revised acetabular components. Eighty-eight patients (100 hips) underwent isolated revision of the acetabular components for polyethylene wear and osteolysis of the acetabulum. The study group consisted of 70 men and 18 women with a mean age of 52.8 years (range, 31-54 years) when the primary total hip arthroplasty was performed. Evidence of fretting and corrosion of the trunnion of all prostheses was examined macroscopically using a magnifying lens. Degree of fretting and corrosion of the trunnion was assessed using a 4-point scoring technique. A new 36-mm alumina delta ceramic head was implanted on the trunnion of a well-fixed stem without using a titanium adapter sleeve in all hips. The mean follow-up after revision of the acetabular component was 12.8 years (range, 10-14 years). Among the 100 new ceramic heads implanted on a well-fixed stem, no fracture of the ceramic head occurred at a mean follow-up of 12.8 years. The median fretting and corrosion scores for the trunnions were 1.5 +/- 1.1 and 1.3 +/- 0.9 points, respectively. The mean Harris hip score at the final follow-up was 89 +/- 15 points (range, 63-100 points). Survivorship of the revised acetabular components at 14 years was 95% (95% confidence interval, 87.6%-98.6%).
- DOI
- 10.3928/01477447-20180501-03
- Appears in Collections:
- 의과대학 > 의학과 > Journal papers
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML