View : 1149 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author신상진*
dc.date.accessioned2018-02-08T16:32:14Z-
dc.date.available2018-02-08T16:32:14Z-
dc.date.issued2018*
dc.identifier.issn0942-2056*
dc.identifier.issn1433-7347*
dc.identifier.otherOAK-19535*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/239877-
dc.description.abstractEstimation of anterior glenoid bone loss is important for surgical decision-making. The purpose of this study was to describe a method for estimating anterior glenoid bone loss. Thirty-nine cadaveric glenoids were digitized to obtain glenoid geometry. Glenoid bare spot centre, arthroscopic centre, and centre of the inferior glenoid circle relative to the geometric centre were measured. To simulate anterior glenoid bone loss, imaginary sequential osteotomies were created 0A degrees, 22.5A degrees, and 45A degrees to the superior-inferior line in a 3D digitizing programme. Per cent of anterior glenoid bone loss area was calculated as the percentage of defect area relative to the entire area of the glenoid. The relationship between area loss and ratio of bone defect length to the distance from posterior glenoid to various centres was determined. As the ratio of bone defect length to the distance from posterior glenoid to all three centres increased, the per cent area of bone loss increased exponentially. The ratio using the inferior circle centre and arthroscopic centre was highly correlated to the actual glenoid bone loss in all osteotomies (R (2) > 0.90). The ratio using the centre of bare area had the lowest correlation. The ratio of defect length to distance from posterior glenoid to arthroscopic centre greater than 2.4 for 0A degrees and 2.0 for 45A degrees osteotomies results in bone loss area greater than 25 %. The bare area centre had the largest variation. Average bone loss was overestimated when the centre of bare spot was used compared to other centre locations. Per cent of anterior glenoid bone loss can be estimated using the ratio of bone defect length to the distance from posterior glenoid rim to the centre of inferior glenoid circle or arthroscopic centre either preoperatively using 3D CT or arthroscopically which can be useful for determining surgical treatment.*
dc.languageEnglish*
dc.publisherSPRINGER*
dc.subjectGlenoid bone loss*
dc.subjectInstability*
dc.subjectCadaver study*
dc.subjectBony defect*
dc.titleEstimation of anterior glenoid bone loss area using the ratio of bone defect length to the distance from posterior glenoid rim to the centre of the glenoid*
dc.typeArticle*
dc.relation.issue1*
dc.relation.volume26*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage48*
dc.relation.lastpage55*
dc.relation.journaltitleKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY*
dc.identifier.doi10.1007/s00167-016-4312-x*
dc.identifier.wosidWOS:000419453000008*
dc.identifier.scopusid2-s2.0-84991325532*
dc.author.googleShin, Sang-Jin*
dc.author.googleJun, Bong Jae*
dc.author.googleKoh, Young Won*
dc.author.googleMcGarry, Michelle H.*
dc.author.googleLee, Thay Q.*
dc.contributor.scopusid신상진(24074946200)*
dc.date.modifydate20240422113915*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE