Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 차은숙 | - |
dc.contributor.author | 정진 | - |
dc.date.accessioned | 2017-12-27T16:30:49Z | - |
dc.date.available | 2017-12-27T16:30:49Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 0033-8419 | - |
dc.identifier.other | OAK-21515 | - |
dc.identifier.uri | https://dspace.ewha.ac.kr/handle/2015.oak/239372 | - |
dc.description.abstract | Purpose: To investigate the value of the combined use of elastography and color Doppler ultrasonography (US) with B-mode US for evaluation of screening US-detected breast masses in women with dense breasts. Materials and Methods: This prospective, multicenter study included asymptomatic women with dense breasts who were referred for screening US between November 2013 and December 2014. Eligible women had a newly detected breast mass at conventional B-mode US screening, for which elastography and color Doppler US were performed. The following outcome measures were compared between B-mode US and the combination of B-mode US, elastography, and color Doppler US: area under the receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), and the number of false-positive findings at screening US. Results: Among 1021 breast masses (mean size, 1.0 cm; range, 0.3-3.0 cm) in 1021 women (median age, 45 years), 68 were malignant (56 invasive). Addition of elastography and color Doppler US to B-mode US increased the AUC from 0.87 (95% confidence interval [CI]: 0.82, 0.91) to 0.96 (95% CI: 0.95, 0.98; P<001); specificity from 27.0% (95% CI: 24.2%, 29.9%) to 76.4% (95% CI: 73.6%, 79.1%; P<.001) without loss in sensitivity (95% CI: 21.5%, 1.5%; P>.999); and PPV from 8.9% (95% CI: 7.0%, 11.2%) to 23.2% (95% CI: 18.5%, 28.5%; P<.001), while avoiding 67.7% (471 of 696) of unnecessary biopsies for nonmalignant lesions. Conclusion: Addition of elastography and color Doppler US to B-mode US can increase the PPV of screening US in women with dense breasts while reducing the number of false-positive findings without missing cancers. | - |
dc.language | English | - |
dc.publisher | RADIOLOGICAL SOC NORTH AMERICA | - |
dc.title | Evaluation of Screening US-detected Breast Masses by Combined Use of Elastography and Color Doppler US with B-Mode US in Women with Dense Breasts: A Multicenter Prospective Study | - |
dc.type | Article | - |
dc.relation.issue | 2 | - |
dc.relation.volume | 285 | - |
dc.relation.index | SCIE | - |
dc.relation.index | SCOPUS | - |
dc.relation.startpage | 660 | - |
dc.relation.lastpage | 669 | - |
dc.relation.journaltitle | RADIOLOGY | - |
dc.identifier.doi | 10.1148/radiol.2017162424 | - |
dc.identifier.wosid | WOS:000413472000033 | - |
dc.identifier.scopusid | 2-s2.0-85032179381 | - |
dc.author.google | Lee, Su Hyun | - |
dc.author.google | Chung, Jin | - |
dc.author.google | Choi, Hye Young | - |
dc.author.google | Choi, Seon Hyeong | - |
dc.author.google | Ryu, Eun Bi | - |
dc.author.google | Ko, Kyung Hee | - |
dc.author.google | Koo, Hye Ryoung | - |
dc.author.google | Park, Jeong Seon | - |
dc.author.google | Yi, Ann | - |
dc.author.google | Youk, Ji Hyun | - |
dc.author.google | Son, Eun Ju | - |
dc.author.google | Chu, A. Jung | - |
dc.author.google | Chang, Jung Min | - |
dc.author.google | Cho, Nariya | - |
dc.author.google | Jang, Myoung-jin | - |
dc.author.google | Kook, Shin Ho | - |
dc.author.google | Cha, Eun Suk | - |
dc.author.google | Moon, Woo Kyung | - |
dc.contributor.scopusid | 차은숙(7003760752) | - |
dc.contributor.scopusid | 정진(35573055900) | - |
dc.date.modifydate | 20230210134810 | - |