View : 779 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author김준식*
dc.contributor.author박장원*
dc.date.accessioned2016-12-27T02:12:36Z-
dc.date.available2016-12-27T02:12:36Z-
dc.date.issued2017*
dc.identifier.issn0883-5403*
dc.identifier.issn1532-8406*
dc.identifier.otherOAK-19910*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/233190-
dc.description.abstractBackground: The purpose of this study was to determine: validated clinical and radiographic outcomes of periprosthetic femoral fractures around stable hip implants treated with plate fixation and additional cortical strut onlay allografts without revision of the stem; radiographic signs of fracture healing; allograft-to-host bone union; resorption of cortical strut allograft; and frequency of complications. Methods: At our institute, 24 patients (25 hips) were identified with Vancouver type B1 fracture at the tip of the femoral stem and one patient (one hip) was identified with a Vancouver type C fracture of the femur. All these fractures were treated with combined use of locking plate fixation and cortical strut onlay allografts. There were 18 women and 7 men, with an average age of 63 years. Harris hip score and University of California, Los Angeles activity score were used to assess postoperative function. The average duration of follow-up was 3.7 years (range, 1-7 years). Results: Harris hip score at final review was 86 points (range, 65-95 points). University of California, Los Angele activity score averaged 5.8 +/- 1.3 point (range, 3.5-10 points) at final follow-up. All but 2 patients returned to their preoperative functional level within 1 year. Twenty-three of 26 hips had fracture union following the first operation. Three hips were failed to obtain fixation because of insufficient length of plate and allograft. Cortical strut onlay allografts were incorporated in the host femur in all hips by one year. Minor resorption of allograft was noticed, but there was no failure of any of the cortical strut allografts. Conclusion: The cortical strut onlay allografts facilitated the mechanical stability and the biological fracture healing in addition to plate fixation. (C) 2016 Elsevier Inc. All rights reserved.*
dc.languageEnglish*
dc.publisherCHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS*
dc.subjectlocking plate*
dc.subjectstrut onlay allograft*
dc.subjectperiprosthetic fracture*
dc.subjectwell-fixed femoral component*
dc.subjectclinical results*
dc.subjectradiographic results*
dc.titleUse of Locking Plate and Strut Onlay Allografts for Periprosthetic Fracture Around Well-Fixed Femoral Components*
dc.typeArticle*
dc.relation.issue1*
dc.relation.volume32*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.startpage166*
dc.relation.lastpage170*
dc.relation.journaltitleJOURNAL OF ARTHROPLASTY*
dc.identifier.doi10.1016/j.arth.2016.05.064*
dc.identifier.wosidWOS:000392623000031*
dc.identifier.scopusid2-s2.0-85002588174*
dc.author.googleKim, Young-Hoo*
dc.author.googleMansukhani, Sameer Ajit*
dc.author.googleKim, Jun-Shik*
dc.author.googlePark, Jang-Won*
dc.contributor.scopusid김준식(8516905600;57191682200)*
dc.contributor.scopusid박장원(55645949000)*
dc.date.modifydate20240220120149*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE