Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박은진 | * |
dc.date.accessioned | 2016-08-29T12:08:54Z | - |
dc.date.available | 2016-08-29T12:08:54Z | - |
dc.date.issued | 2015 | * |
dc.identifier.issn | 0022-3913 | * |
dc.identifier.other | OAK-18768 | * |
dc.identifier.uri | https://dspace.ewha.ac.kr/handle/2015.oak/231626 | - |
dc.description.abstract | Statement of problem: Few studies have compared the marginal and internal fits of crowns fabricated from machinable palladium-silver-indium (Pd-Ag-In) semiprecious metal alloy. Purpose: The purpose of this clinical study was to evaluate and compare the marginal and internal fits of machined Pd-Ag-In alloy, zirconia, and cast gold crowns. Material and methods: A prospective clinical trial was performed on 35 participants and 52 abutment teeth at 2 centers. Individuals requiring prosthetic restorations were treated with gold alloy or zirconia crowns (2 control groups) or Pd-Ag-In alloy crowns (experimental group). A replica technique was used to evaluate the marginal and internal fits. The buccolingual and mesiodistal cross-sections were measured, and a noninferiority comparison was conducted. Results: The mean marginal gaps were 68.2 μm for the gold crowns, 75.4 μm for the zirconia crowns, and 76.9 μm for the Pd-Ag-In alloy crowns. In the 5 cross-sections other than the distal cross-section, the 2-sided 95% confidence limits for the differences between the Pd-Ag-In alloy crowns and the 2 control groups were not larger than the 25-μm noninferiority margin. The control groups displayed smaller internal gaps in the line angle and occlusal spaces compared with the Pd-Ag-In crown group. Conclusion: The marginal gaps of machinable Pd-Ag-In alloy crowns did not meet the noninferiority criterion in the distal margin compared with zirconia and gold alloy crowns. Nonetheless, all 3 crowns had clinically applicable precision. © 2015 Editorial Council for the Journal of Prosthetic Dentistry. | * |
dc.language | English | * |
dc.publisher | Mosby Inc. | * |
dc.title | Clinical evaluations of cast gold alloy, machinable zirconia, and semiprecious alloy crowns: A multicenter study | * |
dc.type | Article in Press | * |
dc.relation.index | SCIE | * |
dc.relation.index | SCOPUS | * |
dc.relation.journaltitle | Journal of Prosthetic Dentistry | * |
dc.identifier.doi | 10.1016/j.prosdent.2015.10.018 | * |
dc.identifier.scopusid | 2-s2.0-84969940615 | * |
dc.author.google | Park J.-M. | * |
dc.author.google | Hong Y.-S. | * |
dc.author.google | Park E.-J. | * |
dc.author.google | Heo S.-J. | * |
dc.author.google | Oh N. | * |
dc.contributor.scopusid | 박은진(22980964700) | * |
dc.date.modifydate | 20240301081003 | * |